The presence of Macro prolactin is a significant cause of elevated prolactin resulting in misdiagnosis in all automated systems. Poly ethylene glycol (PEG) pretreatment is the preventive process but such process includes the probability of loss of a fraction of bioactive prolactin. Surprisingly, PEG treated EQAS & IQAS samples in Cobas e 411 are found out to be correlating with direct results of at least 3 immunoassay systems and treated and untreated Cobas e 411 results are comparable by a correlation coefficient. Comparison of EQAS, IQAS and patient samples were done to find out the trueness of such correlation factor. Study with patient's results have established the correlation coefficient is valid for very small concentration of prolactin also. Materials and methods EQAS, IQAS and 150 patient samples were treated with PEG and prolactin results of treated and untreated samples obtained from Roche Cobas e 411. 25 patient's results (treated) were compared with direct results in Advia Centaur, Architect I & Access2 systems. Statistical calculations Correlation coefficient was obtained from trend line of the treated and untreated results. Two tailed p-value obtained from regression coefficient(r) and sample size. Results and discussion The correlation coefficient is in the range (0.761-0.771). Reverse correlation range is (1.289-1.301). r value of two sets of calculated results were 0.995. Two tailed p- value is zero approving dismissal of null hypothesis. Conclusion The z-score of EQAS does not always assure authenticity of resultsPEG precipitation is correlated by the factor 0.761 even in very small concentrationsAbbreviationsGFCgel filtration chromatographyPEGpolyethylene glycolEQASexternal quality assurance systemM-PRLmacro prolactinPRLprolactinECLIAelectro-chemiluminescence immunoassayCLIAclinical laboratory improvement amendmentsIQASinternal quality assurance systemrregression coefficient.
منابع مشابه
The Effect of pH on the Liquid-liquid Equilibrium for a System Containing Polyethylene Glycol Di-methyl Ether and Tri-potassium Citrate and its Application for Acetaminophen Separation
In this work liquid-liquid equilibrium for aqueous two phase system composed of polyethylene glycol di-methyl ether and tri-potassium citrate at different medium pH values (6.00, 7.00 and 8.00) and 298.15 K was studied. The obtained results show that two phase area expanded with an increasing of pH values. The performances of the Merchuk and semi-empirical equations were tested in correlating t...
متن کاملFormulation, Physiochemical, and Microbial Assay of Henna Oil Vaginal Suppository Formulated with Polyethylene Glycol Bases
Background: Persian Medicine is one of the oldest and richest complementary and alternative options in the field of medicine and has a comprehensive medical system. Henna oil is recommended in Persian Medicine for the treatment of numerous women’s diseases such as cervicitis. To date, henna has been used for many medical purposes, including astringent, bleeding, cardioinhibitory, hypotension, a...
متن کاملYarn pulling out test and numerical solution of penetration into woven fabric target impregnated with shear thickening fluid using SiO2 /Polyethylene Glycol
In this paper, finite element model of woven fabric target has been investigated which is impacted by a cylindrical projectile. Fabrics are impregnated with Shear Thickening Fluid (STF). The effects of the (STF) have been considered as frictional effect. The STF has been made (Nano Silica and Polyethylene Glycol (PEG)) and then diluted by ethanol proportion of 3:1. Yarn pulling out test from in...
متن کاملEvaluation of protein corona formation and anticancer efficiency of curcumin-loaded zwitterionic silica nanoparticles
Objective(s): Study and development of antifouling nanosystem for conjugation of drugs were attracting great attention in recent years. The present study aimed to develop novel curcumin-loaded silica nanoparticles containing zwitterionic coating as an antifouling system to provide protein corona free nanoformulations for curcumin. Materials and Methods: Silica nanoparticles were prepared ...
متن کاملQuantification of Polyethylene Glycol Esters of Methotrexate and Determination of Their Partition Coefficients by Validated HPLC Methods
Conjugation of methotrexate (MTX) (MW 454) with different molecular weights of polyethylene glycol (PEG) including methoxy-peg (mpeg) 750 D and 5000 D and diol-peg 35000 D led to compounds that are physicochemically highly different from the parent compound, MTX. In this study, an HPLC system consisting of C8 column and UV detector (?=342 nm), using a mixture of 30:70 v/v phosphate-citrate buff...