Endovascular Embolization of Intracranial Aneurysms Using Bare Platinum Axium™ Detachable Coils: Immediate and Short-Term Follow-up Results from a Multicenter Registry

نویسندگان

  • Byung Moon Kim
  • Dong Joon Kim
  • Pyoung Jeon
  • Pyung Ho Yoon
  • Byung Hee Lee
  • Myeong Sub Lee
  • Tae Hong Lee
  • Jun Soo Byun
  • Dong Ik Kim
چکیده

PURPOSE Axium™ coils were developed to improve the durability of coil-embolized cerebral aneurysms by increasing packing density. The purpose of this prospective multicenter registry was to evaluate the safety and durability of Axium™ coils. MATERIALS AND METHODS One hundred twenty-six patients with 135 aneurysms of ≤ 15 mm in size underwent coil embolization using bare platinum coils, with Axium™ coils constituting over 50% of the total coil length. Immediate and short-term follow-up results were prospectively registered and retrospectively evaluated. RESULTS Of the 135 aneurysms (83 unruptured and 52 ruptured), immediate post-embolization angiography revealed complete occlusion in 80 aneurysms (59.3%), neck remnants in 47 (34.8%), and incomplete occlusion in 8 (5.9%). The mean packing density was 42.8% (range, 9.5 - 90%) with Axium™ coil length constituting a mean of 87.9% of total coil length. The rate of procedure-related complications was 16.3%. Procedure-related permanent morbidity and mortality rates were 3.2% and 0.8%, respectively. Follow-up catheter or MR angiography, which was available in 101 aneurysms at 6 - 15 months (mean, 7.7 months), revealed stable or improved occlusion in 95 aneurysms and worsening in 6 aneurysms (5.9%). Lower packing density (< 30%) remained the only predictor for anatomical worsening on multivariable logistic regression analysis (P < 0.05). CONCLUSION In this registry, Axium™ coils showed a relatively low rate of anatomical worsening on short-term follow-up imaging with an acceptable periprocedural safety profile compared to reports of other platinum coils. These results may warrant further study of long-term durability with Axium™ coils in larger populations.

منابع مشابه

Endovascular treatment of intracranial aneurysms with matrix detachable coils: immediate posttreatment results from a prospective multicenter registry.

BACKGROUND AND PURPOSE Endovascular treatment of intracranial aneurysms by using detachable coils has become an accepted alternative to surgery. To reduce the rate of aneurysm recanalization after treatment, biologically active polyglycolic/polylactic acid-covered platinum coils have been proposed. A prospective and multicenter registry was conducted in France to evaluate the safety and short-t...

متن کامل

Matrix detachable coils for the endovascular treatment of intracranial aneurysms: analysis of early angiographic and clinical outcomes.

BACKGROUND AND PURPOSE Endovascular coil embolization has become an accepted alternative for the treatment of intracranial aneurysms. The purpose of this study was to evaluate the clinical safety and the angiographic stability of aneurysm occlusion with a new class of biologically active platinum coils after a 6-month period. METHODS Twenty-five patients with 25 intracranial aneurysms were tr...

متن کامل

Endovascular treatment of intracranial aneurysms with matrix detachable coils: midterm anatomic follow-up from a prospective multicenter registry.

BACKGROUND AND PURPOSE Polyglycolic/polylactic acid-covered platinum coils have been proposed to reduce the rate of aneurysm recanalization after endovascular treatment. A prospective and multicenter registry was conducted in France to evaluate the safety and short-term and midterm efficacy of Matrix coils. This analysis focused on anatomic midterm results. MATERIALS AND METHODS Two hundred t...

متن کامل

Endovascular treatment with bare platinum coils for middle cerebral artery aneurysms.

Middle cerebral artery (MCA) aneurysms often have unfavorable anatomical characteristics preventing successful endovascular occlusion. We reviewed the outcomes of our series of endosaccular embolization of MCA aneurysms using bare platinum coils, angiographic images, and medical records. Immediate and follow-up angiographic results were categorized as complete occlusion, residual neck, and resi...

متن کامل

Short-term outcome of intracranial aneurysms treated with polyglycolic acid/lactide copolymer-coated coils compared to historical controls treated with bare platinum coils: a single-center experience.

BACKGROUND AND PURPOSE Aneurysm recanalization is an innate problem in endovascular treatment of aneurysms with coils. A coated coil system, covered with a bioabsorbable polymeric material (polyglycolic acid/lactide copolymer, PGLA), was developed to accelerate intra-aneurysmal clot organization and fibrosis. The purpose of this study was to evaluate the efficacy and safety of the PGLA-coated c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

متن کامل
عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2012