A new modular six-bar linkage trans-femoral prosthesis for walking and squatting.

نویسندگان

  • J K Chakraborty
  • K M Patil
چکیده

Four-bar linkage mechanisms produced by many designers of knee joints for trans-femoral prostheses can provide knee rotation to permit walking only. In Afro-Asian countries people are accustomed to a squatting posture in their daily activities. A six-bar linkage knee-ankle mechanism trans-femoral prosthesis is described which was developed and fitted to an amputee. The motion patterns of the ankle, knee and thigh during walking and squatting (obtained using a flickering light emitting diode system) for the above prosthesis is compared with motion patterns obtained for normal subjects. The closeness between both the patterns establishes the suitability of the new modular trans-femoral prosthesis for producing near normal patterns of motion during walking and squatting. The additional facility of cross-legged sitting provided in the prosthesis makes it functionally suitable for Afro-Asian amputees.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simulation of Human Foot Mechanism with a Degree of Freedom Motion

The need for simulation of human foot mechanism has made researchers and engineers move towards different patterns to describe this movement. In this regard, optimal solutions such as energy consumption, accuracy, etc. are of utmost importance. In this paper, efforts have been made to present a new solution by designing a fully two-dimensional six-bar mechanism with one degree of freedom so tha...

متن کامل

Subjective benefits of energy storing prostheses.

The energy storing (ES) prosthesis has been used in the Prosthetic Foundation's workshop since 1987. Subjective responses from 168 amputees (141 trans-tibial and 27 trans-femoral) fitted with the ES prosthesis were analysed. Ratings were generally favourable in comparison with those for conventional prostheses. The most pronounced advantages of the new prosthesis as shown by the ratings were in...

متن کامل

Evaluation of a Viscoelastic Ankle-Foot Prosthesis at Slow and Normal Walking Speeds on an Able-Bodied Subject

Objectives: This paper describes further improvement and preliminarily evaluation of a novel viscoelastic ankle-foot prosthesis prototype. The objective was to control the ankle hysteresis at slow and normal walking speeds. Methods: Inspired by the ankle biomechanics, in which the hysteresis differs based on the gait speeds, a manually damping control mechanism imbedded in the prosthesis for...

متن کامل

Comparing the Effect of New Silicone Foot Prosthesis and Conventional Foot Prosthesis on Plantar Pressure in Diabetic Patients With Transmetatarsal Amputation

Objective Diabetic foot ulcers are significant complications of diabetes that can lead to amputation. Partial foot prostheses can be used to redistribute the plantar pressure on the residual limb to alleviate local pressures and prevent re-amputation at more proximal levels. The current study aimed to describe the fabrication of an original silicone foot prosthesis designed for a diabetic patie...

متن کامل

Feedback error learning neural network for trans-femoral prosthesis.

Feedback-error learning (FEL) neural network was developed for control of a powered trans-femoral prosthesis. Nonlinearities and time-variations of the dynamics of the plant, in addition to redundancy and dynamic uncertainty during the double support phase of walking, makes conventional control methods very difficult to use. Rule-based control, which uses a knowledge base determined by machine ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Prosthetics and orthotics international

دوره 18 2  شماره 

صفحات  -

تاریخ انتشار 1994