Use of a local indicator dilution technique for the measurement of oscillatory flow.
نویسنده
چکیده
An indicator dilution method for measuring oscillatory flow in a vessel is analyzed in terms of a mixing chamber with a constant volume. For the correct measurement of mean flow, the time constant of detection of the indicator Should be very much shorter than the shortest time constant of the mixing volume. The performance of such a system was examined with a thermal indicator. Although the apparent mixing volume was found not to be constant but to vary with flow, the method showed no significant error in the measurement of mean flow. There was no significant "distance distortion error" when the indicator was detected at two different points downstream from the site of infusion; this was attributed to the pattern of mixing, with detection within or close to the limits of the mixing volume. It is concluded that a properly designed indicator dilution system can measure mean blood flow without significant error, even when there is an oscillatory component. ADDITIONAL
منابع مشابه
Measurement of Myocardial Blood Flow
A"CLOSED" method for the accurate measurement of myocardial blood flow is still to be achieved. In 1956, Henly et al. described an indicator-dilution technique for assessing myocardial blood flow. This approach led us to construct a suitable model for simulating a systemic-coronary circuit. Observations with this system suggested that an indicator-dilution technique might be applicable to measu...
متن کاملDetermining the Reference Value in Forest Policy of Kalgachi Local System, Zagros Forest, Chaharmahal and Bakhtiari Province
Sustainable forest management standards and measurement instruments subject and use them as the main tool is very important for monitoring and control in forest management. Sustainable progress monitoring and measuring possible by tools and standards. Tools and standards to help sustainable forest management can be more accurate and better information provided to forest managers and decision-ma...
متن کاملTechnical note: measuring portal blood flow in sheep using an ultrasonic transit time flow probe.
Our objective was to validate the use of an ultrasonic transit-time flowmeter for the measurement of portal blood flow (PBF) in sheep. Data recorded with this technique were compared with those obtained with an indicator dilution method, and probes were calibrated in vivo. Wethers were fitted with catheters in the portal, jejunal, and ruminal veins and in a mesenteric artery. Ultrasonic flow pr...
متن کاملOscillatory MHD Flow of Blood through an Artery with Mild Stenosis (RESEARCH NOTE)
The purpose of this work is to study the effect of oscillatory MHD blood flow in stenosed artery. The analytical and numerical results are obtained for oscillatory MHD blood flow, which is assumed to be a Newtonian fluid. It was also assumed that the surface roughness is of cosine shaped and the maximum height of roughness is negligible, compared with the radius of un-constricted tube. The flui...
متن کاملEstimation of Flow Zone Indicator Distribution by Using Seismic Data: A Case Study from a Central Iranian Oilfield
Flow unit characterization plays an important role in heterogeneity analysis and reservoir simulation studies. Usually, a correct description of the lateral variations of reservoir is associated with uncertainties. From this point of view, the well data alone does not cover reservoir properties. Because of large well distances, it is difficult to build the model of a heterogenic reservoir, but ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation research
دوره 22 1 شماره
صفحات -
تاریخ انتشار 1968