Expulsion of the disk of a Bjork-Shiley aortic prosthesis after temporary removal.
نویسندگان
چکیده
A 42-year-old woman was diagnosed by cardiac catheterization as having severe mitral stenosis and grade-3/4 aortic regurgitation. The patient underwent mitral commissurotomy and replacement of the aortic valve with a No. 21 Bj#{246}rkShiley tilting-disk prosthesis. The prosthesis was fixed in place with 16 single sutures (Ethiflex). In the immediate postoperative period the clinical picture and the phonocardiogram suggested significant aortic regurgitation. Repeat surgery was performed 13 days after the first procedure. It was discovered that an excessively large space existing between two of the sutures was responsible for the leak. In order to gain better access to this zone, we decided to remove the disk; we also rotated the valve within the sewing ring with the valvular holder designed by the manufacturer for this purpose. The leak was closed with a U suture, the disk was put back into position, and it was left functioning normally, being apparently well held in place, The patient was discharged from the hospital ten days later, without any evidence of aortic regurgitation. Seventeen days after the second operation, the patient was awakened from her sleep by a nightmare, and seconds later she lost consciousness. She was readmitted to our hospital in cardiac arrest. All manipulations to induce recovery failed, and the patient died. The autopsy revealed that the disk had dislodged from the rest of the prosthesis and had come to rest in the abdominal aorta. On examination of the valve, an excessive clearance between the struts and the disk was discovered.
منابع مشابه
Twelve-year comparison of a Bjork-Shiley mechanical heart valve with porcine bioprostheses.
BACKGROUND Patients undergoing heart-valve replacement may receive a mechanical prosthesis, necessitating lifelong anticoagulant treatment, or a porcine bioprosthesis, which involves no absolute need for anticoagulants. METHODS We carried out a randomized, prospective trial to compare the durability of the Bjork-Shiley mechanical prosthesis (spherical tilting-disk model) and the incidence of ...
متن کاملCARDIOVASCULAR MEDICINE Twenty year comparison of a Bjork-Shiley mechanical heart valve with porcine bioprostheses
Objective: To compare survival and outcome in patients receiving a mechanical or bioprosthetic heart valve prosthesis. Design: Randomised prospective trial. Setting: Tertiary cardiac centre. Patients: Between 1975 and 1979, patients were randomised to receive either a Bjork-Shiley or a porcine prostheses. The mitral valve was replaced in 261 patients, the aortic in 211, and both valves in 61 pa...
متن کاملLate thrombosis of the aortic Bjork-Shiley prosthesis. Its clinical recognition and management.
Seven cases of massive thrombosis of an aortic Bjork-Shiley prosthesis were encountered among 433 valvular implants. Four patients died before treatment could be instituted, and three underwent repeat surgery successfully. Anticoagulation therapy was probably well maintained in four, and poorly maintained in three patients. These cases illustrated the need for a high index of suspicion and prom...
متن کاملResults of use of the pyrolytic carbon tilting disc Bjork-Shiley aortic prosthesis.
Replacement of the aortic valve with a new BjorkShiley prosthesis was performed in 1 10 patients during the period from November, 1971 to July, 1973. The previously reported Delrin-disc Bjork-Shiley valve had a built-in valvular leak of up to 10 percent due to .003” clearance. The new pyrolite-disc prosthesis is machined to a clearance of .001”. Excellent clinical results have been achieved in ...
متن کاملHaemolysis with Björk-Shiley and Starr-Edwards prosthetic heart valves: a comparative study.
Slater, S. D., Saflam, I. A., Bain, W. H., Turner, M. A., and Lawrie, T. D. V. (1974). Thorax, 29, 624-632. Haemolysis with Bjork-Shiley and Starr-Edwards prosthetic heart valves: a comparative study. A comparison was made of the haemolytic complications in 85 patients with two different types of Starr-Edwards cloth-covered ball and cage prosthesis with those in 44 patients with the Bjork-Shile...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Chest
دوره 73 1 شماره
صفحات -
تاریخ انتشار 1978