Influence of implantation site and track geometry on the extrusion rate and pharmacology of testosterone implants.

نویسندگان

  • S Kelleher
  • A J Conway
  • D J Handelsman
چکیده

BACKGROUND Implantation of testosterone pellets under the lateral abdominal wall skin is an old but popular and effective form of androgen replacement therapy. Extrusion of one or more pellets remains the most frequent adverse event. OBJECTIVE To determine whether an alternative implantation site (hip) and/or track geometry (two vs. four tracks) would reduce extrusion rates compared with the standard of a four-track abdominal site. Additionally, the study aimed to evaluate the effects of site and track geometry on other adverse effects (bruising, infection) and the pharmacology of testosterone release from the implants. DESIGN A prospective, parallel-group unmasked study design in a single centre. The primary objective was to evaluate sites, with evaluation of track geometry a subordinate objective made necessary by anatomical differences. Accordingly, androgen deficient men requiring testosterone implantation with the standard dose (four 200 mg pellets) were randomized into one of three groups (ratio 1 : 1 : 2): a four-track abdomen site (standard), a two-track abdomen site or a two-track hip site. The pharmacological substudy was to evaluate the impact of site and track geometry on testosterone implant pharmacology by monthly hormone assays following implantation. PATIENTS Two hundred and forty-six implantation procedures involving 96 androgen deficient men. MEASUREMENTS The primary end-point, extrusion rate per procedure, and secondary end-points (bruising or infection post procedure) were evaluated prospectively by self-report from the participants, and verified when they returned next for implantation. The pharmacology substudy involved monthly blood sampling for hormone (total and free testosterone, LH, FSH) measurements. RESULTS The extrusion rate was significantly higher [odds ratio (OR) = 2.6, 95% confidence interval (CI) 1.1-7.1] for the hip site (15/125, 12%) compared with the abdominal site (6/121, 5%). Track geometry made no significant difference (OR = 1.05, 95% CI 0.2-5.4) to the extrusion rate. No secondary end-points (bruising, infection) were significantly different according to either site or track geometry. One operator who performed the implant procedures had significantly less primary and secondary adverse events than the other operators (P = 0.006). Neither implantation site, nor track geometry influenced pharmacokinetics [peak plasma total and free testosterone concentrations and net hormone release (area-under-curve, AUC)] or pharmacodynamics [nadir plasma LH and FSH and net suppression (AUC) in men with hypergonadotrophic hypogonadism]. CONCLUSIONS We conclude that the hip site has a higher extrusion rate than the standard abdominal wall site but that track geometry does not increase the risk of extrusion. Neither implantation site, nor track geometry influenced either other adverse effects or the pharmacokinetics or pharmacodynamics of testosterone pellet implants.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Testosterone release rate and duration of action of testosterone pellet implants.

OBJECTIVE Testosterone pellets are a highly effective subdermal depot administered at regular intervals with the timing individualized depending upon return of the patient's characteristic androgen deficiency symptoms. Yet the in vivo testosterone release rate and effective duration of action of these pellets has been little studied systematically. DESIGN Analysis of prospectively collected d...

متن کامل

Extrusion of testosterone pellets: a randomized controlled clinical study.

BACKGROUND It has previously been shown that testosterone implantation is an effective and well accepted form of androgen replacement therapy, but that pellet extrusion was the most frequent side-effect. The present study aimed to reduce the extrusion rate. OBJECTIVE To determine whether the washing of testosterone pellets to remove potentially surface-adherent particles decreased the rate of...

متن کامل

Influences of Track Structure, Geometry and Traffic Parameters on Railway Deterioration

The roles of the several parameters that influences railway track deterioration most, are examined in this research with a view to make railway track maintenance more effective and cost efficient. The results presented are based on a comprehensive study of railway track degradation on super structure, sub-structure and geometrical aspects. The changes in TQI (Track Quality Index), the track set...

متن کامل

Hot-Melt Extrusion Technique: A Review

Hot-melt extrusion is one of the most widely applied processing technologies in the plastic, rubber and food industry. Today this technology has found its place in the array of pharmaceutical manufacturing operations. Melt extrusion process are currently applied in the pharmaceutical field for the manufacture of a variety of dosage forms and formulations such as granules, pellets, tablets, supp...

متن کامل

Hot-Melt Extrusion Technique: A Review

Hot-melt extrusion is one of the most widely applied processing technologies in the plastic, rubber and food industry. Today this technology has found its place in the array of pharmaceutical manufacturing operations. Melt extrusion process are currently applied in the pharmaceutical field for the manufacture of a variety of dosage forms and formulations such as granules, pellets, tablets, supp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical endocrinology

دوره 55 4  شماره 

صفحات  -

تاریخ انتشار 2001