Incorporating a Patient Dichotomous Characteristic in Cancer Phase I Clinical Trials Using Escalation with Overdose Control

نویسندگان

  • Mourad Tighiouart
  • Galen Cook-Wiens
  • André Rogatko
  • Yichuan Zhao
چکیده

We describe a design for cancer phase I clinical trials that takes into account patients heterogeneity thought to be related to treatment susceptibility. The goal is to estimate the maximum tolerated dose MTD given patient’s specific dichotomous covariate value. The design is Bayesian adaptive and is an extension of escalation with overdose control EWOC . We will assess the performance of this method by comparing the following designs via extensive simulations: 1 design using a covariate; patients are accrued to the trial sequentially and the dose given to a patient depends on his/her baseline covariate value, 2 design ignoring the covariate; patients are accrued to the trial sequentially and the dose given to a patient does not depend on his/her baseline covariate value, and 3 design using separate trials; in each group, patients are accrued to the trial sequentially and EWOC is implemented in each group. These designs are compared with respect to safety of the trial and efficiency of the estimates of the MTDs via extensive simulations. We found that ignoring a significant baseline binary covariate in the model results in a substantial number of patients being overdosed. On the other hand, accounting for a nonsignificant covariate in the model has practically no effect on the safety of the trial and efficiency of the estimates of the MTDs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dose escalation with overdose control using a quasi-continuous toxicity score in cancer Phase I clinical trials.

Escalation with overdose control (EWOC) is a Bayesian adaptive design for selecting dose levels in cancer Phase I clinical trials while controlling the posterior probability of exceeding the maximum tolerated dose (MTD). EWOC has been used by clinicians to design many cancer Phase I clinical trials, see e.g. [1-4]. However, this design treats the toxicity response as a binary indicator of dose ...

متن کامل

Adaptive Estimation of Personalized Maximum Tolerated Dose in Cancer Phase I Clinical Trials Based on All Toxicities and Individual Genomic Profile

BACKGROUND Many biomarkers have been shown to be associated with the efficacy of cancer therapy. Estimation of personalized maximum tolerated doses (pMTDs) is a critical step toward personalized medicine, which aims to maximize the therapeutic effect of a treatment for individual patients. In this study, we have established a Bayesian adaptive Phase I design which can estimate pMTDs by utilizin...

متن کامل

Advanced Designs of Cancer Phase I and Phase II Clinical Trials

The clinical trial is the most import study for the development of successful novel drugs. The aim of this dissertation is to develop innovative statistical methods to overcome the three main obstacles in clinical trials: (1) lengthy trial duration and inaccurate maximum tolerated dose (MTD) in phase I trials; (2) heterogeneity in drug effect when patients are given the same prescription and sa...

متن کامل

Escalation with Overdose Control Using Time to Toxicity for Cancer Phase I Clinical Trials

Escalation with overdose control (EWOC) is a Bayesian adaptive phase I clinical trial design that produces consistent sequences of doses while controlling the probability that patients are overdosed. However, this design does not take explicitly into account the time it takes for a patient to exhibit dose limiting toxicity (DLT) since the occurrence of DLT is ascertained within a predetermined ...

متن کامل

Toxicity‐dependent feasibility bounds for the escalation with overdose control approach in phase I cancer trials

Phase I trials of anti-cancer therapies aim to identify a maximum tolerated dose (MTD), defined as the dose that causes unacceptable toxicity in a target proportion of patients. Both rule-based and model-based methods have been proposed for MTD recommendation. The escalation with overdose control (EWOC) approach is a model-based design where the dose assigned to the next patient is one that, gi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014