The corneal volume and biomechanical corneal factors: Is there any orrelation?

نویسندگان

  • Mohammad Reza Sedaghat
  • Maria Sharepoor
  • Samira Hassanzadeh
  • Mojtaba Abrishami
چکیده

BACKGROUND The aim of this study was to determine the correlation between corneal hysteresis (CH) and the corneal resistance factor (CRF), which are both novel methods of analyzing ocular rigidity/elasticity, and various corneal characteristics, mainly corneal volume in normal subjects. METHODS This cross-sectional study included 500 normal eyes of volunteers. An ocular response analyzer (ORA) was used to measure CH and CRF. Patient age and the Pentacam-measured corneal volume (CV), posterior elevation, anterior elevation, corneal curvature, central corneal thickness (CCT), corneal thickness of apex (CTA), and corneal thinnest thickness (CTT) were compared with CH and CRF. Statistical significance was defined at p < 0.05. RESULTS The mean CH and CRF for all eyes were 9.9 ± 1.4 mmHg and 10.1 ± 1.6 mmHg, respectively. The mean CVs of the 3, 5, 7, and 10 mm zones for all eyes were 3.8 ± 0.2 mm(3), 11.2 ± 0.6 mm(3), 24.3 ± 1.4 mm(3), and 60.1 ± 3.5 mm(3), respectively. The correlations between CV and the hysteresis or CRF were significant in all zones. The CV of the 7-mm zone had the strongest correlation with CH (r = 0.438) and the CV of the 5-mm zone had the strongest correlation with CRF (r = 0.574). CONCLUSIONS CH and CRF correlate with CV. Moreover, the correlation between CV and CRF is stronger than that between CV and CH. The CV may be valuable for determining patient's qualification for and predicting the outcome of refractive surgery. It would also be helpful in other cases in which corneal biomechanics are important.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ویژگی‌های بیومکانیکی قرنیه در بیماران مبتلا به کراتوکونوس و ارتباط آن با شدت بیماری

Background and Objective: Keratoconus is a disorder in cornea characterized by constant thinning and prominence that can result in vision defect. Due to ultrasonic changes in the corneal structure caused by keratoconus disease, its rigidity and biomechanical properties are subject to some changes. In this regard, the present study was conducted to determine the correlation of biomechanical feat...

متن کامل

اندازه‌گیری قطر افقی قرنیه نوزادان ایرانی

  Introduction : Horizontal corneal diameter is one of the diagnostic factors in some ophthalmic diseases. At present American Newborn horizontal corneal diameter is considered as our normal value in Iranian ones, while it may be quite different in Iranian newborns. Early diagnosis is critical in some ophthalmic diseases such as congenital glaucoma and awareness of normal corneal diameter is es...

متن کامل

Correlation of Corneal Allograft Rejection with Tumor Necrosis Factors-Alpha Gene Polymorphism

Background: Correlations between bone marrow, heart, kidney, liver, skin and lung transplant rejection or survival with human cytokine gene polymorphisms have been described. There are also reports about the role of cytokines and Tumor Necrosis Factors-Alpha (TNF-α) on corneal transplant in animal models. Further studies are needed to clarify the role of cytokines in corneal allograft rejection...

متن کامل

Effects of eye rubbing and breath holding on corneal biomechanical properties and intraocular pressure.

PURPOSE To determine whether corneal biomechanical properties and intraocular pressure (IOP) are affected by eye rubbing and breath holding. METHODS Corneal hysteresis, corneal resistance factor, corneal compensated IOP (IOPcc), and Goldmann equivalent IOP (IOPg) were measured on both eyes of 40 subjects. Measurements were taken at baseline before eye rubbing (ER(0)) and before breath holding...

متن کامل

درمان کدورت های قرنیه با استفاده از لیزر اکسایمر

PTK (Phototherapeutic Keratectomy) is the use of laser in corneal diseases. We can replace PTK for many other invasive procedures. The objective of this study is the assessment of this procedure in several cases in our practice. This investigation was a retrospective study, which was conducted based on comparison of 11 eyes with corneal eschars, induced by recurrent corneal erosions, pterygium ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2012