Frictional resistance of self-ligating versus conventional brackets in different bracket-archwire-angle combinations

نویسندگان

  • Maria Regina Guerra MONTEIRO
  • Licinio Esmeraldo da SILVA
  • Carlos Nelson ELIAS
  • Oswaldo de Vasconcellos VILELLA
چکیده

OBJECTIVE To compare the influence of archwire material (NiTi, beta-Ti and stainless steel) and brackets design (self-ligating and conventional) on the frictional force resistance. MATERIAL AND METHODS Two types of brackets (self-ligating brackets - Smartclip, 3M/Unitek - and conventional brackets - Gemini, 3M/Unitek) with three (0, 5, and 10 degrees) slot angulation attached with elastomeric ligatures (TP Orthodontics) were tested. All brackets were tested with archwire 0.019"x0.025" nickel-titanium, beta-titanium, and stainless steel (Unitek/3M). The mechanical testing was performed with a universal testing machine eMIC DL 10000 (eMIC Co, Brazil). The wires were pulled from the bracket slots at a cross-head speed of 3 mm/min until 2 mm displacement. RESULTS Self-ligating brackets produced significantly lower friction values compared with those of conventional brackets. Frictional force resistance values were directly proportional to the increase in the bracket/ wire angulation. With regard to conventional brackets, stainless steel wires had the lowest friction force values, followed by nickel-titanium and beta-titanium ones. With regard to self-ligating brackets, the nickel-titanium wires had the lowest friction values, significantly lower than those of other materials. CONCLUSION even at different angulations, the self-ligating brackets showed significantly lower friction force values than the conventional brackets. Combined with nickel-titanium wires, the self-ligating brackets exhibit much lower friction, possibly due to the contact between nickel-titanium clips and wires of the same material.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Self-ligation esthetic brackets with low frictional resistance.

OBJECTIVE To test the frictional resistance forces (FRS) generated between several archwires and (1) interactive self-ligating (ISL) brackets and (2) conventionally ligated (CL) brackets. MATERIALS AND METHODS Frictional forces produced between three different archwire combinations and self-ligating (SL) brackets (ceramic and metal-slot or all-metal) and CL brackets (metal or ceramic) were ev...

متن کامل

Evaluation of friction in orthodontics using various brackets and archwire combinations-an in vitro study.

AIM The aim of this study was to compare frictional resistance which was produced between conventional brackets (0.022 slot Otho-Organiser) and self ligating brackets (active Forestadent and passive Damon III) by using various arch wire combinations (0.016 Niti, 0.018 Niti, 0.017 x 0.025 SS and 0.019 x 0.025 SS). METHODS An experimental model which consisted of 5 aligned stainless steel 0.022...

متن کامل

Third-order torque and self-ligating orthodontic bracket-type effects on sliding friction.

OBJECTIVE To examine the influence of third-order torque on kinetic friction in sliding mechanics involving active and passive self-ligating brackets. MATERIALS AND METHODS Wire-slot frictional forces were quantified and compared across five sets of brackets and tubes within a simulated posterior dental segment with -15 degrees , -10 degrees , -5 degrees , 0 degrees , +5 degrees , +10 degrees...

متن کامل

Frictional Resistance of Three Types of Ceramic Brackets

OBJECTIVES To investigate the static frictional resistance at the bracket/archwire interface in two recently introduced bracket systems and compare them to conventional ceramic and conventional metal bracket systems. Three variables were considered including the bracket system, archwire type and archwire angulation. MATERIAL AND METHODS Four bracket systems were tested in vitro: Self ligating...

متن کامل

Friction between various self-ligating brackets and archwire couples during sliding mechanics.

INTRODUCTION The aim of this study was to evaluate the frictional resistance between active and passive self-ligating brackets and 0.019 × 0.025-in stainless steel archwire during sliding mechanics by using an orthodontic sliding simulation device. METHODS Maxillary right first premolar active self-ligating brackets In-Ovation R, In-Ovation C (both, GAC International, Bohemia, NY), and SPEED ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 22  شماره 

صفحات  -

تاریخ انتشار 2014