Cardiac output during labour.

نویسندگان

  • S C Robson
  • W Dunlop
  • R J Boys
  • S Hunter
چکیده

Serial measurements of cardiac output and mean arterial pressure were performed in 15 women during the first stage of labour and at one and 24 hours after delivery. Cardiac output was measured by Doppler and cross sectional echocardiography at the pulmonary valve. Basal cardiac output (between uterine contractions) increased from a prelabour mean of 6.99 l/min to 7.88 l/min at greater than or equal to 8 cm of cervical dilatation as a result of an increase in stroke volume. Over the same period basal mean arterial pressure also increased. During uterine contractions there was a further increase in cardiac output as a result of increases in both stroke volume and heart rate. The increment in cardiac output during contractions became progressively greater as labour advanced. At greater than or equal to 8 cm of dilatation cardiac output increased from a basal mean of 7.88 l/min to 10.57 l/min during contractions. There were also further increases in mean blood pressure during contractions. One hour after delivery heart rate and cardiac output had returned to prelabour values, though mean arterial pressure and stroke volume remained raised. By 24 hours after delivery all haemodynamic variables had returned to prelabour values. Haemodynamic changes of the magnitude found in this series are of considerable clinical relevance in managing mothers with complicated cardiovascular function.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Central circulatory responses in normotensive and hypertensive pregnancy.

Haemodynamic responses in normotensive pregnancy in the antenatal phase show that cardiac output is elevated by the end of the first trimester, and remains elevated throughout pregnancy, although it may fall very slightly at the end of the third trimester of pregnancy. Heart rate remains virtually static throughout pregnancy, although it may fall very slightly at the end of the third trimester ...

متن کامل

مقایسه تغییرات برون‌ده قلبی در 2 روش بیهوشی با هالوتان و پروپوفول در بیماران تحت عمل ترمیم روتاتورکاف در وضعیت نشسته با روش غیرتهاجمی

Maintenance of cardiac output in normal range to assure tissues and vital organ perfusion is one of the most important tasks of anesthetists. Hemodynamic and cardiac indices(e.g. cardiac output) change due to either anesthetic drugs or changes in body position during various surgical operations and they have also been important and notable problems. The goal of the present study was...

متن کامل

Percutaneous interventions in stenotic valvular heart disease complicating pregnancy.

Heart disease complicating pregnancy is a common and serious clinical condition. Cardiac disease does not preclude pregnancy but increases the risk to both the mother and the foetus, despite state-of-the-art obstetric and cardiac care. The incidence of maternal heart disease in Sri Lanka is about 1.5 per hundred deliveries. About 70% are of rheumatic origin [1]. It causes chronic valvular lesio...

متن کامل

The Effect of the Timing of Intramuscular Oxytocin Injection on Maternal Bleeding during the Third Stage of Labour

Background and aim: The third stage of labour is one of the most troublesome stages of child delivery. The basic principle of the third stage management is administrating prophylactic uterotonics. However, the time of its administration varies in different hospitals. This study aimed to determine the effect of intramuscular oxytocin injection after emergence of the fetal anterior shoulder or pl...

متن کامل

Evaluation of the Effect of Atenolol Induced Depression in Cardiac Output on Its Own Excretion through Urine Analysis

The role of Pharmacist in making the therapeutic decisions for safe and effective therapy is increasing all over the world. However, there are many aspects of drugs in making these decisions that are less commonly studied such as the correlation of cardiac output with pharmacokinetics of drugs. The cardiac output, besides the other factors, is also affected by drugs like atenolol. Therefore, th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British medical journal

دوره 295 6607  شماره 

صفحات  -

تاریخ انتشار 1987