KeraRing intrastromal corneal ring segments for correction of keratoconus.

نویسندگان

  • Almutez M Gharaibeh
  • Sana' M Muhsen
  • Ilham B AbuKhader
  • Osama H Ababneh
  • Mohammed A Abu-Ameerh
  • Muawyah D Albdour
چکیده

PURPOSE Intrastromal corneal ring segments (ICRSs) are small arc-like implants that are being used increasingly as a minimally invasive treatment for patients with keratoconus. This study assessed the effectiveness of KeraRing implants, a type of ICRS, to treat keratoconus. METHODS Retrospective case series descriptive study of 43 patients (55 eyes) with keratoconus who underwent KeraRing implantation from February 2008 to June 2009. Patients who had intraoperative or postoperative complications and/or did not complete at least 6 months of follow-up were excluded. All patients underwent complete ophthalmologic examinations that included measurement of the uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), manifest refraction, and keratometry before and 2 days, 2 weeks, 1 month, and 3 and 6 months after surgery. The ring segments were chosen based on a nomogram from the manufacturer. RESULTS Six months postoperatively, the mean UCVA increased significantly (P < 0.05) from 0.10 ± 0.11 to 0.32 ± 0.25 and the mean BSCVA increased from 0.36 ± 0.23 to 0.57 ± 0.24 (P < 0.05). The mean spherical refractive error significantly (P < 0.05) improved from -4.85 ± 2.90 diopters (D) to -1.89 ± 2.68 D, and the mean cylindrical refractive error significantly (P < 0.05) improved from -3.65 ± 1.70 D to -2.60 ± 1.62 D. The mean spherical equivalent significantly (P < 0.05) decreased from -6.68 ± 2.93 D to -3.19 ± 2.75 D, and the mean keratometry value decreased from 51.83 ± 4.14 D to 47.27 ± 3.68 D. The improvement in the UCVA and BSCVA continued over the 6-month postoperative period, but significant changes occurred only during the first 3 months. These changes occurred in patients with all grades of keratoconus. CONCLUSIONS KeraRing implantation provided significant improvement in visual acuity, spherical equivalent, and keratometry results. This ICRS is an effective treatment for managing keratoconus and might delay or even avoid the need for penetrating keratoplasty.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intrastromal corneal ring segment implantation by femtosecond laser for keratoconus correction.

PURPOSE To report the outcomes after the implantation of intrastromal corneal ring segments (KERARING) aided by femtosecond laser for the correction of keratoconus. DESIGN Prospective consecutive interventional study. PARTICIPANTS Twenty-one eyes of 16 consecutive keratoconic patients with mean age 32+/-10.2 years. Forty-five percent were keratoconus grade I, 20% grade II, 15% grade III, an...

متن کامل

Outcome of Keraring Intrastromal Corneal Ring Segment Implantation for the Management of Keratoconus

Objective: To report the outcome of Keraring intrastromal corneal ring segment implantation using mechanical tunnel creation method for the management of keratoconus. Patients and Methods: This study was conducted during the period from July 2009 to November 2011 at Dhahran Eye Specialist Hospital, Dhahran, Saudi Arabia. It included 38 patients (40 eyes) with keratoconus who underwent Keraring ...

متن کامل

Intrastromal corneal ring segments and posterior chamber phakic intraocular lens implantation for keratoconus correction.

PURPOSE To evaluate the efficacy, safety, and predictability of sequential implantation of Keraring intrastromal corneal ring segments (ICRS) and an Implantable Collamer Lens phakic intraocular lens (pIOL) with corneal relaxing incisions for refractive correction of keratoconus. SETTING Fernández-Vega Ophthalmological Institute, Oviedo, Spain. DESIGN Cohort study. METHODS This study compr...

متن کامل

Combined femtosecond laser-assisted intracorneal ring segment implantation and corneal collagen cross-linking for correction of keratoconus

PURPOSE To assess the safety, predictability, and effectiveness of Keraring intrastromal corneal ring segments (ICRS) insertion assisted by femtosecond laser and corneal collagen cross-linking (CXL) for keratoconus correction. PATIENTS AND METHODS In this prospective, noncomparative, and interventional case series, 160 eyes of 100 adult keratoconus patients with poor best-corrected visual acu...

متن کامل

Complications of intrastromal corneal ring segment implantation using a femtosecond laser for channel creation: a survey of 850 eyes with keratoconus.

PURPOSE To report complications after the implantation of intrastromal corneal ring segments (Keraring; Mediphacos, Belo Horizonte, Brazil) in keratoconic eyes using a femtosecond laser (IntraLase; Advanced Medical Optics, Santa Ana, California, USA) for channel creation. METHODS Retrospective chart review of 531 patients (850 eyes) who underwent Keraring insertion using a femtosecond laser f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Cornea

دوره 31 2  شماره 

صفحات  -

تاریخ انتشار 2012