HUT fully polarimetric calibration standard for microwave radiometry

نویسندگان

  • Janne Lahtinen
  • Martti Hallikainen
چکیده

This paper describes the Helsinki University of Technology’s Fully Polarimetric Calibration Standard (FPCS). The developed standard generates a complete Stokes reference vector and it is applied for the end-to-end absolute calibration of a fully polarimetric microwave radiometer at 36.5 GHz. The FPCS is based on the function principle of a Gasiewski–Kunkee linearly polarized (tripolarimetric) standard, with an additional phase retardation plate to generate the fourth Stokes parameter. Design considerations and operational aspects of the standard are discussed in this paper. An advanced calibration procedure, which takes advantage of both the tripolarimetric and fully polarimetric calibration scenes to suppress calibration uncertainties, is introduced. The feasibility of the standard has been verified and the generated brightness temperatures in a sample calibration are presented. An extensive set of tests has been performed to evaluate the characteristics and performance of the calibration standard. Furthermore, the use of the advanced calibration procedure to measure the characteristics of the phase retardation plate has been successfully demonstrated. The achievable calibration accuracy is analyzed and discussed relative to requirements for maritime wind vector measurements; the results indicate that the pixel-to-pixel retrieval of the wind speed is possible with high accuracy and the retrieval of the wind direction with at least moderate accuracy. In addition to calibration of a fully polarimetric radiometer, other potential applications, e.g., linearity measurements, are discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A calibration method for fully polarimetric microwave radiometers

A technique for absolute end-to-end calibration of a fully polarimetric microwave radiometer is presented. The technique is based on the tripolarimetric calibration technique of Gasiewski and Kunkee, but is extended to provide a means of calibrating all four Stokes parameters. The extension is facilitated using a biaxial phase-retarding microwave plate to provide a precisely known fourth Stokes...

متن کامل

A correlated noise calibration standard for interferometric, polarimetric, and autocorrelation microwave radiometers

A new type of calibration standard is presented which produces a pair of microwave noise signals to aid in the characterization and calibration of correlating radiometers. The Correlated Noise Calibration Standard (CNCS) is able to generate pairs of broad bandwidth stochastic noise signals with a wide variety of statistical properties. The CNCS can be used with synthetic aperture interferometer...

متن کامل

Polarimetric Microwave Radiometer Calibration

A polarimetric radiometer is a radiometer with the capability to measure the correlation information between vertically and horizontally polarized electric fields. To better understand and calibrate this type of radiometer, several research efforts have been undertaken. 1) All microwave radiometer measurements of brightness temperature (7B) include an additive noise component. The variance and ...

متن کامل

Verification of L-band Fully Polarimetric Noise Injection Radiometer Measurement Capability

Abstract A functional test to verify the proper and accurate measurement capability of an L-band fully polarimetric noise injection radiometer is presented. The test is designed specifically for the MDPP-2 (MIRAS Demonstrator Pilot Project 2) NIR (Noise Injection Radiometer), which has two functions: (1) to calibrate the MIRAS (Microwave Imaging Radiometer using Aperture Synthesis) instrument b...

متن کامل

Polarimetric Van Atta Reflector for Airborne Sar Calibration

Polarimetric synthetic aperture radar (SAR) has to be calibrated before its applications. This paper presents a novel reference target of Van Atta array design for calibration of airborne polarimetric SAR. It has capabilities of two-dimensional radio source tracking, 90-degree polarization rotation while retransmitting, and suppressing scattered fields from array elements and supporting structu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • IEEE Trans. Geoscience and Remote Sensing

دوره 41  شماره 

صفحات  -

تاریخ انتشار 2003