Observation on the effect of digitalis on sinus node function by recording of twenty-four hour continuous electrocardiogram.

نویسندگان

  • K Otsuka
  • T Yanaga
چکیده

Twenty-four hour recording of electrocardiogram was performed in 5 cases, aged from 42 to 75 years, with paroxysmal tachyarrhythmias (paroxysmal supraventricular tachycardia (PSVT) 2 cases and paroxysmal atrial fibrillation (PAf) 3 cases) for the purpose of assessing the effects of digitalis on sinus node function from the chronobiological point of view. All of the pauses following the termination of PSVT or PAf observed during a day were measured in 4 cases as the sinus node recovery time (SNRT). Corrected sinus node recovery time (CSNRT) was determined by subtracting the penultimate P-P cycle length from the SNRT. Both SNRT and CSNRT were prolonged in all cases after digitalis administration. In 1 case observation on the diurnal variation of SNRT and CSNRT showed the most marked prolongation of these values at 6:00 a.m. after digitalis administration. The second degree of SA block was observed in 2 cases in the early morning after digitalis treatment. In the other 2 cases sinoatrial conduction time (SACT) was calculated by the use of premature atrial contraction and corrected by dividing by the basic cycle length before and after digitalis administration. Neither SACT and CSACT showed significant differences between the values before and after the treatment in 2 cases, nor the diurnal variation of SACT and CSACT showed significant differences. Above results suggest that digitalis should be used with caution in patients with paroxysmal tachyarrhythmia because even small amounts of digitalis might provoke sinus node dysfunction. Twenty-four hour recording of electrocardiogram is useful in the earlier recognition of sinus node dysfunction induced by digitalis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

HOLTER MONITORING IN DIGITALIS - PROVOKED ARRHYTHMIAS 555 The Role of Holter Monitoring in Detecting

Certain arrhythmias detected on the electrocardiogram are considered to be reliable indicators of digitalis intoxication. We have evaluated the incidence of these arrhythmias on 24-hour electrocardiographic monitoring (Holter monitoring) in 69 consecutive patients who had serum levels of digoxin determined within 24 hours of the onset of continuous electrocardiographic monitoring. According to ...

متن کامل

Digitalis and the sick sinus syndrome. Clinical and electrophysiologic documentation of severe toxic effect on sinus node function.

Digoxin, in a common clinical dose and at a low serum level, brought out severe manifestations of sinus node dysfunction in a patient who had previously undergone successful mitral valve replacement. This report presents the results of extensive clinical and electrophysiologic studies of this patient before and after a digoxin challenge. In the absence of cardiac glycoside, the only demonstrabl...

متن کامل

Tape monitoring of the electrocardiogram in ambulant patients with sinoatrial disease.

Continuous tape recording of the electrocardiogram was carried out on 25 patients with sinus bradycardia or sinoatrial block. A 72-hour record was made on each fully ambulant patient, by a miniature portable tape recorder and the tapes processed with automatic dysrhythmia detection. A high incidence of slow and fast sinaatrial dysrhythmias was discovered and brief episodes of atrial tachydysrhy...

متن کامل

Clinical and Electrophysiologic Documentation of a Severe Toxic Effect on Sinus Node Function

was followed by sinus pauses in excess of six seconds, even at relatively slow overdrive pacing rates. The electrophysiologic and clinical implications of these data are discussed. It is suggested that despite previous reports that digitalis preparations are relatively well tolerated by patients with sick sinus syndrome, caution should be used when administering these drugs to this group of pat...

متن کامل

On the effect of low-quality node observation on learning over incremental adaptive networks

In this paper, we study the impact of low-quality node on the performance of incremental least mean square (ILMS) adaptive networks. Adaptive networks involve many nodes with adaptation and learning capabilities. Low-quality mode in the performance of a node in a practical sensor network is modeled by the observation of pure noise (its observation noise) that leads to an unreliable measurement....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Japanese heart journal

دوره 18 3  شماره 

صفحات  -

تاریخ انتشار 1977