Reducing dose to the lungs through loosing target dose homogeneity requirement for radiotherapy of non small cell lung cancer

نویسندگان

  • Junjie Miao
  • Hui Yan
  • Yuan Tian
  • Pan Ma
  • Zhiqiang Liu
  • Minghui Li
  • Wenting Ren
  • Jiayun Chen
  • Ye Zhang
  • Jianrong Dai
چکیده

It is important to minimize lung dose during intensity-modulated radiation therapy (IMRT) of nonsmall cell lung cancer (NSCLC). In this study, an approach was proposed to reduce lung dose by relaxing the constraint of target dose homogeneity during treatment planning of IMRT. Ten NSCLC patients with lung tumor on the right side were selected. The total dose for planning target volume (PTV) was 60 Gy (2 Gy/fraction). For each patient, two IMRT plans with six beams were created in Pinnacle treatment planning system. The dose homogeneity of target was controlled by constraints on the maximum and uniform doses of target volume. One IMRT plan was made with homogeneous target dose (the resulting target dose was within 95%-107% of the prescribed dose), while another IMRT plan was made with inhomogeneous target dose (the resulting target dose was more than 95% of the prescribed dose). During plan optimization, the dose of cord and heart in two types of IMRT plans were kept nearly the same. The doses of lungs, PTV and organs at risk (OARs) between two types of IMRT plans were compared and analyzed quantitatively. For all patients, the lung dose was decreased in the IMRT plans with inhomogeneous target dose. On average, the mean dose, V5, V20, and V30 of lung were reduced by 1.4 Gy, 4.8%, 3.7%, and 1.7%, respectively, and the dose to normal tissue was also reduced. These reductions in DVH values were all statistically significant (P < 0.05). There were no significant differences between the two IMRT plans on V25, V30, V40, V50 and mean dose for heart. The maximum doses of cords in two type IMRT plans were nearly the same. IMRT plans with inhomogeneous target dose could protect lungs better and may be considered as a choice for treating NSCLC.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Concurrent chemoradiotherapy in locally advanced non-small cell lung cancer: a retrospective analysis of the correlation between radiotherapy-related factors and tumor response

Background: To determine which radiotherapy parameters are associated with the tumor response of locally advanced non-small cell lung cancer (NSCLC) patients undergoing concurrent chemoradiotherapy. Materials and Methods: Thirty one patients with IIIA/IIIB NSCLC underwent chemoradiotherapy with a median dose of 63 Gy. On our actual treatments, we made radiotherapy planning to cover the planning...

متن کامل

Intensity modulated radiation therapy (IMRT) technique for left breast cancer by different numbers of beam fields

Background: Intensity Modulated Radiotherapy (IMRT) can improve radiotherapy (RT) results by improving healthy tissue sparing. Additionally, IMRT provides more consistent dose deliveries and suppresses secondary tumor formation. RT is a principal treatment in breast cancer (BC). Aim: To evaluate the outcome of the Radiotherapy Plans (RTP) that use IMRT technique to left breast and other organs,...

متن کامل

Evaluating Performance of Algorithms in Lung IMRT: A Comparison of Monte Carlo, Pencil Beam, Superposition, Fast Superposition and Convolution Algorithms

Background: Inclusion of inhomogeneity corrections in intensity modulated small fields always makes conformal irradiation of lung tumor very complicated in accurate dose delivery.Objective: In the present study, the performance of five algorithms via Monte Carlo, Pencil Beam, Convolution, Fast Superposition and Superposition were evaluated in lung cancer Intensity Modulated Radiotherapy plannin...

متن کامل

The Comparison 2D and 3D Treatment Planning in Breast Cancer Radiotherapy with Emphasis on Dose Homogeneity and Lung Dose

Introduction: Breast conserving radiotherapy is one of the most common procedures performed in any radiation oncology department. A tangential parallel-opposed pair is usually used for this purpose. This technique is performed using 2D or 3D treatment planning systems. The aim of this study was to compare 2D treatment planning with 3D treatment planning in tangential irradiation in breast conse...

متن کامل

Impacts of multiple-field irradiation and boron concentration on the treatment of boron neutron capture therapy for non-small cell lung cancer

Background: Boron neutron capture therapy (BNCT) is a radiotherapy that combines biological targeting and high linear energy transfer. A potential therapeutic approach for non-small cell lung cancer (NSCLC) is considered. However, dose in lung tumor is not homogeneous, and it will reduce the effect of BNCT treatment. In order to improve the dose distribution of BNCT, the multi-field irradiation...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 18  شماره 

صفحات  -

تاریخ انتشار 2017