Static and Mobile DXA Scanner In-Vivo Cross-Calibration Study

ثبت نشده
چکیده

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of a new body composition phantom for quality control and cross-calibration of DXA devices.

This study evaluated a new body composition phantom and its use for quality control and cross-calibration of dual-energy X-ray absorptiometry (DXA) instruments for measurements of body composition. We imaged the variable composition phantom (Lunar, Madison, WI) on eight different DXA devices. Deviations of up to 7% fat were observed when we compared the percent fat values measured by the differ...

متن کامل

A Physician’s Guide to QCT BMD Testing

Today, QCT is one of three methods, including DXA, cited by the National Osteoporosis Foundation as safe and effective for the evaluation of BMD[3]. The QCT system comprises a CT scanner calibration device and a software application on a standalone Windows PC networked to the CT scanner. At the hip, QCT produces BMD T-Score measurements that are clinically equivalent to DXA measurements[5], but...

متن کامل

Static Calibration and Analysis of the Velodyne HDL-64E S2 for High Accuracy Mobile Scanning

The static calibration and analysis of the Velodyne HDL-64E S2 scanning LiDAR system is presented and analyzed. The mathematical model for measurements for the HDL-64E S2 scanner is derived and discussed. A planar feature based least squares adjustment approach is presented and utilized in a minimally constrained network in order to derive an optimal solution for the laser’s internal calibratio...

متن کامل

Does Exposure to Static Magnetic Fields Generated by Magnetic Resonance Imaging Scanners Raise Safety Problems for Personnel?

MRI workers are occupationally exposed to static and time-varying gradient magnetic fields.  While the 24-hour time-averaged exposure to static magnetic fields is about a few mT, the maximum static field strength can be as high as 500 mT during patient setup. Over the past several years, our laboratory has performed extensive experiments on the health effects of exposure of animal models and h...

متن کامل

Colorimetric Scanner Calibration for Textiles by Neural-Network

In this study, colorimetric calibration of scanner has been done via perceptron neural network with three or four layers by back propagation algorithm for colored polyester fabrics. The results obtained for random training samples are not satisfactory but application of selective training samples for L*a*b* or RGB leads to good results, with better results obtained for the L*a*b* method. On the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014