Virtual respiratory system in investigation of CPAP influence on optimal breathing frequency in obstructive lungs disease
نویسندگان
چکیده
BACKGROUND Continuous Positive Airway Pressure (CPAP) is a commonly accepted method of spontaneous breathing support in obstructive lung disease. Previous work suggested that the cause of the CPAP efficacy in the obstructive lung disease localized in bronchi of middle order (OLDMO) is not as obvious as, for example, in the obstructive sleep apnea. Since CPAP reduces obstruction and the optimal breathing frequency (BF) depends on the obstruction level, it seems to be important to analyze the dependence of the optimal BF on CPAP. AIM To analyze the support efficacy cause in OLDMO, esp. the relationship between the CPAP value and optimal BF. METHOD Investigations utilized previously built virtual respiratory system. Its most important factors: nonlinear lungs compliance and changeability of nonlinear airway resistance (Raw). Influence of BF and the CPAP value on the tidal volume and minute ventilation was analyzed for four exemplary virtual patients: healthy ("standard") and suffering from moderate, severe, and the very severe OLDMO (the other parameters, esp. respiratory muscles effort, were unchanged). Minute inspiratory work as a criterion of the BF optimization. RESULTS CPAP decreased Raw making breathing easier, however, it shifted the working point of the respiratory system towards the smaller lungs compliance making breathing harder. The final result depended on the Raw value: CPAP improved breathing of patients with the serious OLDMO while it worsened healthy person breathing. The optimal CPAP value depended on the Raw value. If a virtual patient suffering from the serious OLDMO was not supported with CPAP, he had to breathe with low frequency because minute ventilation did not rise with BF increase. The optimal BF depended on the CPAP value (the greater the value, the greater the frequency). CONCLUSION The CPAP efficacy depends on the level of OLDMO. CPAP is efficient in the severe OLDMO because it increases the optimal BF, which makes possible less energy-consuming breathing with frequency close to the normal one (greater BF means smaller tidal volume and thus smaller work against lungs compliance).
منابع مشابه
A Model of the Respiratory System in the Newborn Infant
A dynamic mathematical model is presented which successfully simulates the respiratory control system of the newborn infant in different physiological conditions. The primary objective in constructing this model has been to provide a simulation aid in the investigation of maturation of the respiratory system, and the respiratory disorders during the newborn period, without the need for invasive...
متن کاملThe Effect of Motivational Abdominal Breathing Device on Breathing Patterns and Shortness of Breath in Patients with Chronic Obstructive Pulmonary Disease
Background and purpose: Despite the high prevalence of chronic obstructive pulmonary disease, There haven,t been definite curative treatment for the disease and focus of treatment has directed towards pulmonary rehabilitation as an effective non-drug treatments. this study were performed to determine the effect of motivational abdominal breathing device on breathing pattern and dyspnea of chron...
متن کاملEffects of biphasic positive airway pressure in patients with chronic obstructive pulmonary disease.
Biphasic positive airway pressure (BiPAP) is a ventilatory mode in which two pressure levels (higher (Phigh) and lower (Plow)) acting as continuous positive airway pressure (CPAP) alternate at preset time intervals. BiPAP combines pressure-controlled ventilation with unrestricted spontaneous breathing. BiPAP has not yet been evaluated in patients with chronic obstructive pulmonary disease (COPD...
متن کاملImportance of sleep stage- and body position-dependence of sleep apnoea in determining benefits to auto-CPAP therapy.
The influence of sleep stage- and body position-dependence of sleep apnoea on treatment efficacy and compliance between conventional continuous positive airway pressure (CPAP) and auto CPAP therapy was evaluated. Thirty-three newly treated sleep apnoea hypopnoea syndrome (SAHS) patients were randomly allocated to conventional or auto-CPAP therapy. Six patients of each treatment group were class...
متن کاملAcute effects of different levels of continuous positive airway pressure on cardiac autonomic modulation in chronic heart failure and chronic obstructive pulmonary disease
INTRODUCTION Non-invasive ventilation may improve autonomic modulation and ventilatory parameters in severely disabled patients. The aim of the present study was to evaluate the physiological influence of acute treatment with different levels of continuous positive airway pressure (CPAP) on the autonomic balance of heart and respiratory responses in patients with stable chronic obstructive pulm...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Nonlinear Biomedical Physics
دوره 1 شماره
صفحات -
تاریخ انتشار 2007