Osmolality gaps: diagnostic accuracy and long-term variability.

نویسندگان

  • John Krahn
  • Annu Khajuria
چکیده

BACKGROUND The osmolal gap (OG) is a screening test for the detection of toxic volatiles such as methanol and ethylene glycol. We used mean values of patient data to assess the diagnostic accuracy and long-term stability of OG measurements. METHODS In a prospective study period in 2003, all requests for volatiles had OGs calculated and quality-control samples were analyzed for OG. ROC curves were constructed to determine whether OG could predict the presence of toxic volatiles in serum. This was also done in a retrospective study for data from 1996 to 2004. Our laboratory database was searched for all emergency room patients for the period of 1996 to 2004 who had tests ordered that allowed us to calculate OGs. RESULTS For the prospective study period in 2003, the ROC areas indicated that we could accurately predict the presence of toxic volatiles but at markedly different decision cutpoints depending on the formula used. These cutpoints ranged from +10 to +33 mosmol/kg. In the retrospective study, the mean OGs in the patient population for each of the 3 formulas increased by 12 mosmol/kg from 1996 to 2004. For this reason, the diagnostic accuracy was poor when all data were analyzed together. CONCLUSIONS Under properly controlled conditions, the OG has high sensitivity and specificity for detection of poisoning with some volatiles. Over the long term, however, use of the reference interval of -10 to +10 mosmol/kg yields poor diagnostic accuracy because mean OGs are not constant over time. Bedside calculation is not advisable.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Long-term spatial and temporal variability of ambient carbon monoxide in Urmia, Iran

One of the pillars of epidemiologic research on the long-term health effects of air pollution is to estimate the chronic exposures over space and time. In this study, we aimed to measure the intra-urban ambient carbon monoxide (CO) concentrations within Urmia city in Iran, and to build a model within the geographic information system (GIS) to estimate the annual and seasonal means anywhere with...

متن کامل

Water-loss (intracellular) dehydration assessed using urinary tests: how well do they work? Diagnostic accuracy in older people.

BACKGROUND Water-loss dehydration (hypertonic, hyperosmotic, or intracellular dehydration) is due to insufficient fluid intake and is distinct from hypovolemia due to excess fluid losses. Water-loss dehydration is associated with poor health outcomes such as disability and mortality in older people. Urine specific gravity (USG), urine color, and urine osmolality have been widely advocated for s...

متن کامل

The Long-Term Effect of Implicit and Explicit Corrective Feedback on Accuracy of EFL Learners’ Descriptive Writing Skill

Since the emergence of the process-oriented approach to second language writing instruction two main questions have been what and how error feedback should be given to the students. The question of whether teachers should provide feedback on grammar in the writing assignments of English as a foreign language students, and if so how, has been a matter of considerable debate in the field of secon...

متن کامل

Survival of tree seedlings across space and time: estimates from long-term count data

1 Tree diversity in forests may be maintained by variability in seedling recruitment. Although forest ecologists have emphasized the importance of canopy gaps in generating spatial variability that might promote tree regeneration, the effects of canopy gaps on seedling recruitment may be offset by dense forest understories. 2 Large annual fluctuations in recruitment processes, coupled with the ...

متن کامل

Diagnostic accuracy of calculated serum osmolarity to predict dehydration in older people: adding value to pathology laboratory reports

OBJECTIVES To assess which osmolarity equation best predicts directly measured serum/plasma osmolality and whether its use could add value to routine blood test results through screening for dehydration in older people. DESIGN Diagnostic accuracy study. PARTICIPANTS Older people (≥65 years) in 5 cohorts: Dietary Strategies for Healthy Ageing in Europe (NU-AGE, living in the community), Dehy...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 52 4  شماره 

صفحات  -

تاریخ انتشار 2006