Biomechanics of the pulmonary autograft valve in the aortic position.

نویسندگان

  • A Gorczynski
  • M Trenkner
  • L Anisimowicz
  • R Gutkowski
  • A Drapella
  • E Kwiatkowska
  • M Dobke
چکیده

Pulmonary autograft valve replacement has been simulated by implanting the pulmonary valve into the aortic position of the same cadaver heart from both human and porcine sources. The forces acting on the pulmonary valve leaflets have been calculated on the basis of a triaxial ellipsoid mathematical model. These forces on the pulmonary autograft valve were shown to be essentially similar to those previously reported for aortic valve leaflets. Biomechanical measurements have been made on the simulated autograft valves and on the isolated pulmonary valve cusps. The tensile strengths of the pulmonary valve cusps in both circumferential and radial directions were roughly three times greater than those of aortic valve cusps. This indicated the ability of the pulmonary valves to accept, ab initio, aortic valve closing pressures. Pressure-induced changes in dimension, calculated on the basis of diameters of the simulated pulmonary autograft root, also indicated that the distensibility of the autograft valve was limited. It reached a maximum at 30 mm Hg (4 kPa) without any suggestion of further distension to the point of distortion and incompetence. The combination of the calculated forces acting on the valve and the biomechanical measurements have shown that pulmonary valves used as autograft aortic valve replacements are able to tolerate aortic pressures from the time of implantation. These experimental results from simulated autografts support the clinical use of this valve over the past 13 years.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

تعویض دریچه آئورت: مقایسه روش متداول و روش جدید

Background: The usage of pericardium of patient himself, for support of anastomosis lines may carry benefits in patients undergoing aortic valve replacement with pulmonary autograft (Ross). The aim of the present study was to compare the short term results of aortic valve replacement with pulmonary autograft with routine and offered methods. Methods: In a non-randomized clinical trial, 64 pati...

متن کامل

The Ross Operation: Treatment of Choice for Aortic Valve Disease in Children and Young Adults

1 also called the pulmonary autograft procedure, involves replacement of the diseased aortic valve with the patient’s own pulmonary valve (autograft) and implantation of a biological valve (homograft) in the pulmonary position. It was first described and pioneered by Mr. Donald Ross in 1967 in London. The procedure was popularised in the 1980s when homografts became widely available on both sid...

متن کامل

Treatment of impaired coronary blood flow after aortic root replacement with human tissue valves.

Aortic root replacement has been described extensively for aortic allograft or pulmonary autograft insertion.1,2 One of the critical issues of this technique is the correct reimplantation of the coronary artery buttons. Kinking or torsion of the coronary arteries may lead to intraoperative hemodynamic problems or to delayed symptoms including angina pectoris and/or limited exercise tolerance ow...

متن کامل

The role of transesophageal echocardiography during the Ross procedure.

Pulmonary autograft replacement of the aortic valve, the “Ross procedure,” involves transplantation of the native pulmonary valve into the aortic position and reconstruction of the right ventricular outflow tract with a cryopreserved pulmonary or aortic homograft. In any surgeon’s hands this operation is technically challenging and successful performance of the Ross procedure requires strategie...

متن کامل

Pregnancy in patients with pulmonary autograft valve replacement.

AIM The purpose of this study is to determine the outcome and complications of pregnancy in women with pulmonary autograft valve replacement for aortic valve disease. METHODS AND RESULTS The records of all women who had undergone pulmonary autograft valve replacement at the National Heart Hospital (now Royal Brompton Hospital) since 1968 were reviewed. From 1968 to 1993, 27 hospital survivors...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Thorax

دوره 37 7  شماره 

صفحات  -

تاریخ انتشار 1982