Restricted accessed nanoparticles for direct magnetic solid phase extraction of trace metal ions from human fluids followed by inductively coupled plasma mass spectrometry detection.

نویسندگان

  • Ping Yan
  • Man He
  • Beibei Chen
  • Bin Hu
چکیده

Herein, restricted accessed magnetic nanoparticles were synthesized by self-assembly of a non-ionic surfactant (Tween-20) onto the 4-(2-pyridylazo)resorcinol (PAR) functionalized magnetic nanoparticles (MNPs). A series of analytical techniques were employed for the characterization of the as-prepared restricted accessed Fe3O4@SiO2@PAR, and it was found that the as-prepared restricted accessed Fe3O4@SiO2@PAR nanoparticles have a porous structure with a BET surface area of around 99.4 m(2) g(-1), an average pore size of about 6.14 nm and a pore volume of 0.47 cm(3) g(-1). Besides, the prepared restricted accessed Fe3O4@SiO2@PAR showed good size exclusion properties toward proteins, providing application potential for the direct analysis of biological samples. Based on this, a novel method of restricted accessed magnetic solid phase extraction (MSPE) combined with inductively coupled plasma-mass spectrometry (ICP-MS) was developed for the direct determination of trace metal ions in human fluids. The parameters affecting the extraction of the target metals by MSPE were studied and the optimized conditions were established. Under the optimum conditions, the adsorption capacity of Cr(III), Cd(II), La(III), Nd(III) and Pb(II) on the as-prepared restricted accessed Fe3O4@SiO2@PAR was 62.9, 56.6, 33.7, 36.9 and 43.3 mg g(-1), respectively. With an enrichment factor of 30, the limits of detection for Cr(III), Cd(II), La(III), Nd(III) and Pb(II) were as low as 11.9, 0.8, 0.7, 1.6 and 4.1 ng L(-1), and the relative standard deviations were 7.6, 8.7, 8.4, 8.1 and 5.0 (C(Cr, Pb) = 0.05 μg L(-1), C(Cd, La) = 0.005 μg L(-1), C(Nd) = 0.01 μg L(-1), n = 7), respectively. The developed method was successfully applied for the direct analysis of free metal ions in human urine and serum samples, and has the advantages of good anti-interference ability, high sensitivity and exhibits great application potential in the direct analysis of trace metals in biological fluids.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Review of preconcentration and solid phase extraction for the determination of trace Lead

Spectrometric techniques for the analysis of trace lead have developed rapidly due to the increasing need for accurate measurements at extremely low levels of this element in diverse matrices. This review covers separation and preconcentration procedures, and considers the features of the application with several spectrometric techniques. The use of an appropriate sample handling technique is a...

متن کامل

Review of preconcentration and solid phase extraction for the determination of trace Lead

Spectrometric techniques for the analysis of trace lead have developed rapidly due to the increasing need for accurate measurements at extremely low levels of this element in diverse matrices. This review covers separation and preconcentration procedures, and considers the features of the application with several spectrometric techniques. The use of an appropriate sample handling technique is a...

متن کامل

Selective Separation and Preconcentration of trace Amounts of Gallium in Water and Rice Samples using Cloud Point Extraction and Determination by Inductively Coupled Plasma-Atomic Emission Spectrometry

In the present study a cloud-point extraction process using non-ionic surfactant Triton X-114 for selective extraction of gallium from aqueous solutions was developed. The method is based on the complex formation of Ga (III) with N, N′ -bis (salycilidene)-1, 2-phenylenediamine (salophen) as a chelating agent in buffer media of pH 5. After phase separation and dilution of the surfactant-rich pha...

متن کامل

Thiol modified Au nanoparticles grafted manganese doped magnetic iron oxide nanoparticles for spectrometric determination of short-term release of mercury and copper from dental amalgam in saliva

Abstract A new adsorbent, ethylene glycol bisthioglycolate modified gold nanoparticles grafted Mn doped Fe3O4 nanoparticles (EGBTG-Au@Mn-Fe3O4 NPs) were synthesized through chemical precipitation followed by an oxidative Mn doping process to use for extraction and preconcentration of trace amounts of Hg, and Cu ions in artificial and natural saliva. The prepared adsorbent was characterize...

متن کامل

Comparison of Modified Palladium Nanoparticles and Homemade Activated Carbon Derived from Medlar for Solid Phase Extraction of Metal Ions Prior to Their Flame Atomic Absorption Spectrometry Determination

This study focus on the preparation of two supports including activated carbon derived from medlar and Palladium nanoparticles loaded on activated carbon (Pd-NP-AC). Subsequently, both adsorbent modified with a novel Schiff base chelating agent and their potential applicability for determination of trace amounts of metal ions from aqueous solution has been investigated. The method is based on c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Analyst

دوره 140 12  شماره 

صفحات  -

تاریخ انتشار 2015