An integrated microfluidic chip for non-immunological determination of urinary albumin.
نویسندگان
چکیده
This study presents an integrated microfluidic chip for non-immunologically determining the concentrations of albumin in clinical urine samples. This microchip integrates membrane-type micromixers and a fan-shaped micropump capable of simultaneously and precisely delivering assay reagents to react with 6 urine samples in one single operation. The experimental results show that the coefficient of variation in the pumping rate is 2.42%. More importantly, using this unique chip design, only 2 electromagnetic valves are required for the actuation of the micromixer and the micropump. The working range of the proposed microchip is 2-200 mg/L of albumin, which covers the range of interest for the determination of microalbuminuria. Moreover, statistical analysis show that the results obtained by the proposed microchip are in good agreement with the conventional detection method, based on immunological assays. This simple, inexpensive and microchip-based platform presents a promising alternative to conventional immunological assays for measurement of urinary albumin, and is well suited for clinical applications.
منابع مشابه
On-Chip Immunoassay for Determination of Urinary Albumin
An immunoassay performed on a portable microfluidic device was evaluated for the determination of urinary albumin. An increase in absorbance at 500 nm resulting from immunoagglutination was monitored directly on the poly(dimethylsiloxane) (PDMS) microchip using a portable miniature fibre-optic spectrometer. A calibration curve was linear up to 10 mg L(-1) (r(2) = 0.993), with a detection limit ...
متن کاملSelection of aptamers based on a protein microarray integrated with a microfluidic chip.
We developed an efficient and fast method based on a protein microarray integrated with a microfluidic chip for the process of SELEX (systematic evolution of ligands by exponential enrichment). Lactoferrin from bovine milk was used as a target protein, while bovine serum albumin (BSA), α-lactalbumin, β-lactoglobulin and casein were used as negative proteins. They were separately dotted and immo...
متن کاملDevelopment and Application of Integrated Silicon-in-plastic Microfabrication in Polymer Microfluidic Systems
Title of Document: DEVELOPMENT AND APPLICATION OF INTEGRATED SILICON-IN-PLASTIC MICROFABRICATION IN POLYMER MICROFLUIDIC SYSTEMS Likun Zhu, Doctor of Philosophy, 2006 Directed By: Associate Professor Don L. DeVoe, Department of Mechanical Engineering Polymer-based microfluidic devices can offer a number of advantages over conventional devices, and have found many applications in chemical and bi...
متن کاملMicrofluidic Chip-capillary Electrophoresis with Ad- Justable On-chip Sample Dilution for Profiling of Urinary Markers
The paper reports the development of a microfluidic chip-capillary electrophoresis device using UV/Vis detection for profiling of urinary markers with adjustable on-chip sample dilution. A PMMA polymer microfluidic chip-CE device with on-chip ferrofluid valve control for adjustable sample dilution is developed for profiling of urinary markers related to metabolism disorders for clinical diagnos...
متن کاملFluorescent Contrast agent Based on Graphene Quantum Dots Decorated Mesoporous Silica Nanoparticles for Detecting and Sorting Cancer Cells
Background and Objectives: The inability of classic fluorescence-activated cell sorting to single cancer cell sorting is one of the most significant drawbacks of this method. The sorting of cancer cells in microdroplets significantly influences our ability to analyze cancer cell proteins. Material and Methods: We adapted a developed microfluidic device as a 3D in vitro model to sorted MCF-7 c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Biomedical microdevices
دوره 12 5 شماره
صفحات -
تاریخ انتشار 2010