The diagnostic accuracy of multi-frequency bioelectrical impedance analysis in diagnosing dehydration after stroke
نویسندگان
چکیده
BACKGROUND Non-invasive methods for detecting water-loss dehydration following acute stroke would be clinically useful. We evaluated the diagnostic accuracy of multi-frequency bioelectrical impedance analysis (MF-BIA) against reference standards serum osmolality and osmolarity. MATERIAL AND METHODS Patients admitted to an acute stroke unit were recruited. Blood samples for electrolytes and osmolality were taken within 20 minutes of MF-BIA. Total body water (TBW%), intracellular (ICW%) and extracellular water (ECW%), as percentages of total body weight, were calculated by MF-BIA equipment and from impedance measures using published equations for older people. These were compared to hydration status (based on serum osmolality and calculated osmolarity). The most promising Receiver Operating Characteristics curves were plotted. RESULTS 27 stroke patients were recruited (mean age 71.3, SD10.7). Only a TBW% cut-off at 46% was consistent with current dehydration (serum osmolality >300 mOsm/kg) and TBW% at 47% impending dehydration (calculated osmolarity ≥295-300 mOsm/L) with sensitivity and specificity both >60%. Even here diagnostic accuracy of MF-BIA was poor, a third of those with dehydration were wrongly classified as hydrated and a third classified as dehydrated were well hydrated. Secondary analyses assessing diagnostic accuracy of TBW% for men and women separately, and using TBW as a percentage of lean body mass showed some promise, but did not provide diagnostically accurate measures across the population. CONCLUSIONS MF-BIA appears ineffective at diagnosing water-loss dehydration after stroke and cannot be recommended as a test for dehydration, but separating assessment by sex, and using TBW as a percentage of lean body weight may warrant further investigation.
منابع مشابه
بررسی وضعیت هیدراسیون گروههای مختلف شغلی ساکن یزد در فصول زمستان85 و بهار 1386
Introduction: Water is an essential nutrient for life. It comprises 75% of total body weight in infants,60% in adult males and 50% in adult females. Decrease in body water is commonly known as dehydration. Acute or chronic dehydration is a common condition in some population groups, especialy the elderly and those who participate in physical activity in warm enviroments. Potential consequences ...
متن کاملValidity of using multi-frequency bioelectrical impedance analysis to measure skeletal muscle mass in preschool children
[Purposes] Although it is recommended to develop a habit of physical activities, there is no easy way to measure skeletal muscle mass in preschool children, which cause the difficulty of evaluation. The purpose of this study was to examine the validity of body composition including the skeletal muscle mass assessment using multi-frequency bioelectrical impedance analysis by comparing body fat m...
متن کاملValidation of multi-frequency bioelectrical impedance analysis in detecting changes in fluid balance of geriatric patients.
OBJECTIVES Multi-Frequency Bioelectrical Impedance Analysis (MFBIA) is a quick, simple, and inexpensive method to assess body fluid compartments. This study aimed at determining the validity of MFBIA in detecting clinically relevant changes of fluid balance in geriatric patients. DESIGN A prospective, observational study. SETTING The 22-bed Geriatric Department of the University Hospital Ni...
متن کاملBioelectrical impedance analysis for severe stroke patients with upper extremity hemiplegia
[Purpose] This study is to analyze bioimpedance parameters and occupational assessment for severe stroke patients with upper extremity hemiplegia. [Subjects and Methods] Experimental subjects were 20 hemiplegic stroke patients receiving rehabilitation therapy between November to October, 2015. Prediction marker (PM), and phase angle (θ), a nd characteristic frequency (fc) were measured using bi...
متن کاملBioelectrical Impedance versus Body Mass Index for Predicting Body Composition Parameters in Sedentary Job Women
Objective: Nowadays the value of bioelectrical impedance analysis (BIA) in the estimation of body adiposity both on a clinical basis in the individual and epidemiologically in large populations is of great interest. The current study determine accuracy of BIA compared with body mass index (BMI) measurement for estimating body composition in a group of normal weight employee women with a sedenta...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 19 شماره
صفحات -
تاریخ انتشار 2013