Four frequently used test systems for serum cholesterol evaluated by isotope dilution gas chromatography-mass spectrometry candidate reference method.
نویسندگان
چکیده
We evaluated the performance of four frequently used cholesterol test systems, using split-sample measurements with a panel of 79 patients' specimens and isotope dilution gas chromatography-mass spectrometry (ID GS-MS) as a comparison method. The test systems were from Beckman, a Boehringer Mannheim, Merck, and Johnson & Johnson Clinical Diagnostics, performed on the Synchron CX7, Hitachi 717, Mega, and Ektachem 250 analyzers, respectively. The liner regression data for the method comparison [ID GS-MS as independent variable (x)] were for Beckman: slope = 1.012, intercept = 0.0243 mmol/L, dispersion (S(y/x)) = 0.1303 mmol/l, and correlation coefficient (r) = 0.9867; for Boehringer Mannheim: slope = 1.002, intercept = 0.114 mmol/L, Sy/x = 0.0759 mmol/L, r = 0.9954; for Merck: slope = 1.034, intercept = -0.0613 mmol/L, Sy/x = 0.0886 mmol/L, r = 0.9941; and for Johnson & Johnson Clinical Diagnostics: slope = 1.007, intercept = 0.01 mmol/L, Sy/x = 0.15 mmol/L, and r = 0.9811. These data demonstrate excellent state-of-the-art cholesterol measurement for some of the most widely used test systems.
منابع مشابه
Development and evaluation of a candidate reference method for the determination of total cortisol in human serum using isotope dilution liquid chromatography/mass spectrometry and liquid chromatography/tandem mass spectrometry.
Cortisol is an important diagnostic marker for the production of steroid hormones, and accurate measurements of serum cortisol are necessary for proper diagnosis of adrenal function. A candidate reference method involving isotope dilution coupled with liquid chromatography/mass spectrometry (LC/MS) and liquid chromatography/tandem mass spectrometry (LC/MS/MS) has been developed and critically e...
متن کاملTotal cholesterol in serum determined by isotope dilution/mass spectrometry, with liquid-chromatographic separation.
We describe an accurate, precise method for determination of total serum cholesterol by isotope dilution/mass spectrometry (IDMS) with liquid-chromatographic separation. After adding [3,4-13C]cholesterol to serum and hydrolyzing the cholesterol esters, we extract the total cholesterol. "High-performance" liquid chromatography (HPLC) is used to separate the extracted cholesterol for measurement ...
متن کاملDevelopment of a candidate reference measurement procedure for the analysis of cortisol in human serum samples by isotope dilution-gas chromatography-mass spectrometry.
A candidate reference measurement procedure involving isotope dilution coupled with gas chromatography-mass spectrometry (GC-MS) has been developed and critically evaluated. An isotopically labeled internal standard, cortisol-d(2), was added to a serum sample. After equilibration, solid-phase extractions (SPE) for sample preparation and derivatization with heptafluorobutyric anhydride (HFBA) we...
متن کاملCandidate reference methods for determining target values for cholesterol, creatinine, uric acid, and glucose in external quality assessment and internal accuracy control. II. Method transfer.
We describe the testing of transferability of candidate Reference Methods developed by INSTAND for cholesterol, creatinine, uric acid, and glucose. The methods are based on isotope dilution-gas chromatography--mass spectrometry. The study consisted of two parts: setup of the methods and self-evaluation for readiness in the collaborating laboratory, followed by independent measurements in parall...
متن کاملModifications to the NIST reference measurement procedure (RMP) for the determination of serum glucose by isotope dilution gas chromatography/mass spectrometry.
The definitive method (DM), now known as the reference measurement procedure (RMP), for the analysis of glucose in serum was originally published in 1982 by the National Institute of Standards and Technology (NIST). Over the years the method has been subject to a number of modifications to adapt to newer technologies and simplify sample preparation. We discuss here an adaptation of the method a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 42 4 شماره
صفحات -
تاریخ انتشار 1996