Phased-array surface coil MR of the orbits and optic nerves.
نویسندگان
چکیده
PURPOSE To devise a practical technique for high-resolution evaluation of the anterior optic apparatus using a phased-array surface coil system, and to evaluate this system in patients with suspected optic pathway abnormalities. METHODS A four-element phased-array coil pair was placed on each side of the head, and signal-to-noise measurements were obtained using a head phantom. Comparison between the phased-array coil, the quadrature coil, and a single-turn 12.7-cm (5-in) surface coil was done. T1 spin-echo and T2 fast spin-echo sequences were obtained in the oblique axial and oblique sagittal planes, to approximate the long axis of the optic nerves and the nonoblique coronal plane. RESULTS The phantom signal-to-noise measurements at simulated locations of the optic nerve head, optic canal, and optic chiasm revealed an improvement of at least 30% using the phased-array system. Of 24 imaged cases, 9 had trauma, 5 had suspected neoplasms, and 2 had optic neuritis. In 3 patients, an unexpected diagnosis of optic pathway contusion or infarction was made. The remaining 8 patients had various suspected visual pathway lesions. CONCLUSION Phased-array surface coils allow rapid, thin-section imaging of the entire anterior optic pathway, with improved signal-to-noise ratio. This may improve evaluation of optic pathway lesions over conventional techniques.
منابع مشابه
A Two Element Phased Array Coil Enabling Widespread Application of High Resolution MR Coronary Angiography
Parallel imaging using sophisticated receiver coils has improved the clinical feasibility of magnetic resonance coronary angiography (MRCA). These techniques, however, are not readily available outside advanced imaging centers. Our custom-made 2-element phased array coil is readily and inexpensively assembled to address this limitation and enable the widespread application of MRCA. The 2-elemen...
متن کاملPhased-array MRI of canine prostate using endorectal and endourethral coils.
A four-channel phased array consisting of one surface coil, two endorectal coils, and one flexible endourethral loop coil was designed for MRI of the canine prostate. The endorectal coils provide high signal in the posterior region of the prostate, while the endourethral and surface coils are sensitive to the central and anterior regions of the prostate. Gel phantom experiments indicate that th...
متن کاملComparison of 1-d and 2-d surface coil arrays for accelerated volume MR imaging using sensitivity encoding
The optimum phased array combined SNR (B1weighted) [5] and SENSE g-factor were computed for various coil geometries and imaging plane orientations based on simulated field maps. Magnetic fields (B1-maps) for each coil were calculated using the Biot-Savart law. The sample noise correlations between coils which are used in calculating the optimum B1-weighted combining and SENSE g-factor [1] were ...
متن کاملReceive Arrays and Circuitry
Receive coils are one of the most challenging components of the MR system, not only from a technical perspective but also because they are one of the few components in direct contact with the patient containing active electronic circuits. The proximity of the coil to the patient is a fundamental aspect in coil design, which is very often only associated to electronic design. During the past 15 ...
متن کاملMR Spectroscopic Imaging of Peripheral Zone in Prostate Cancer Using a 3T MRI Scanner: Endorectal versus External Phased Array Coils
Magnetic resonance spectroscopic imaging (MRSI) detects alterations in major prostate metabolites, such as citrate (Cit), creatine (Cr), and choline (Ch). We evaluated the sensitivity and accuracy of three-dimensional MRSI of prostate using an endorectal compared to an external phased array "receive" coil on a 3T MRI scanner. Eighteen patients with prostate cancer (PCa) who underwent endorectal...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 16 6 شماره
صفحات -
تاریخ انتشار 1995