Statistical properties of electrically stimulated (ES) and acoustically stimulated (AS) auditory nerve fiber responses were assessed in undeafened and short-term deafened cats, and a detection theory approach was used to determine fibers' abilities to signal intensity changes. ES responses differed from AS responses in several ways. Rate-level functions were an order of magnitude steeper, and discharge rate normally saturated at the stimulus pulse rate. Dynamic ranges were typically 1-4 dB for 200 pps signals, as compared with 15-30 dB for AS signals at CF, and they increased with pulse rate without improving threshold or changing absolute rate-level function slopes. For both ES and AS responses, variability of spike counts elicited by repeated trials increased with level in accord with Poisson-process predictions until the discharge rate exceeded 20-40 spikes/s. AS variability continued increasing monotonically at higher discharge rates, but more slowly. In contrast, maximum ES variability was usually attained at 100 spikes/s, and at higher discharge rates variability reached a plateau that was either maintained or decreased slightly until discharge rate approached the stimulus pulse rate. Variability then decreased to zero as each pulse elicited a spike. Increasing pulse rate did not substantially affect variability for rates up to 800 pps; rather, higher pulse rates simply extended the plateau region. Spike count variability was unusually high for some ES fibers. This was traced to response nonstationarities that stemmed from two sources, namely level-dependent fluctuations in excitability that occurred at 1-3 s intervals and, for responses to high-rate, high-intensity signals, fatigue that arose when fibers discharged at their maximum possible rates. Intensity discrimination performance was assessed using spike count as the decision variable in a simulated 2IFC task. Neurometric functions (percent correct versus intensity difference) were obtained at several levels of the standard (I), and the intensity difference (delta I) necessary for 70% correct responses was estimated. AS Weber fractions (10 log delta I/I) averaged +0.2 dB (delta IdB = 3.1 dB) for 50 ms tones at CF. ES Weber fractions averaged -12.8 dB (delta IdB = 0.23 dB) for 50 ms, 200 pps signals, and performance was approximately constant between 100 and 1000 pps. Intensity discrimination by single cells in ES conditions paralleled human psychophysical performance for similar signals. High ES sensitivity to intensity changes arose primarily from steeper rate-level functions and secondarily from reduced spike count variability.
منابع مشابه
Role of the Internal Superior Laryngeal Nerve in the Motor Responses of Vocal Cords and the Related Voice Acoustic Changes
Background: Repeated efforts by researchers to impose voice changes by laryngeal surface electrical stimulation (SES) have come to no avail. This present pre-experimental study employed a novel method for SES application so as to evoke the motor potential of the internal superior laryngeal nerve (ISLN) and create voice changes.Methods: Thirty-two normal individuals (22 females and 10 males) par...
متن کاملThe responses of horses to predator stimuli
It is not known whether the instincts of wild horses have remained strong during their centuries of domestication. Knowledge of this matter would give riders the opportunity to know more about the behavior of horses and consequently about safety for both horses and riders. In this current research, we studied the behavior of fifteen Caspian miniature horses of different ages and sexes using sti...
متن کاملBinaural interactions of electrically and acoustically evoked responses recorded from the inferior colliculus of guinea pigs.
Binaural interactions within the inferior colliculus (IC) elicited by electric and acoustic stimuli were investigated in this study. Using a guinea pig model, binaural acoustic stimuli were presented with different time delays, as were combinations of binaural electric and acoustic stimuli. Averaged evoked potentials were measured using electrodes inserted into the central nucleus of the IC to ...
متن کاملApplicability of Evoked Auditory Brainstem Responses with Complex Stimuli in Adults with Hearing Loss
The auditory evoked response tests can be classified according to the time taken by the auditory pathway to respond to an acoustic stimulus, whichmay be called short, medium or long latency. The Brainstem Auditory Evoked Response (BAER) is a short-latency, objective and non-invasive test that aims to assess the electrophysiological activity of the auditory system up to thebrainstem. It provides...
متن کاملسایکوآکوستیک و درک گفتار در افراد مبتلا به نوروپاتی شنوایی و افراد طبیعی
Background: The main result of hearing impairment is reduction of speech perception. Patient with auditory neuropathy can hear but they can not understand. Their difficulties have been traced to timing related deficits, revealing the importance of the neural encoding of timing cues for understanding speech. Objective: In the present study psychoacoustic perception (minimal noticeable differen...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of the Acoustical Society of America
دوره 107 2 شماره
صفحات -
تاریخ انتشار 2000