Multi-center evaluation of analytical performance of the Beckman Coulter AU5822 chemistry analyzer.

نویسندگان

  • M K Zimmerman
  • L R Friesen
  • A Nice
  • P A Vollmer
  • E A Dockery
  • J D Rankin
  • K Zmuda
  • S H Wong
چکیده

OBJECTIVES Our three academic institutions, Indiana University, Northwestern Memorial Hospital, and Wake Forest, were among the first in the United States to implement the Beckman Coulter AU5822 series chemistry analyzers. We undertook this post-hoc multi-center study by merging our data to determine performance characteristics and the impact of methodology changes on analyte measurement. DESIGN AND METHODS We independently completed performance validation studies including precision, linearity/analytical measurement range, method comparison, and reference range verification. Complete data sets were available from at least one institution for 66 analytes with the following groups: 51 from all three institutions, and 15 from 1 or 2 institutions for a total sample size of 12,064. RESULTS Precision was similar among institutions. Coefficients of variation (CV) were <10% for 97%. Analytes with CVs >10% included direct bilirubin and digoxin. All analytes exhibited linearity over the analytical measurement range. Method comparison data showed slopes between 0.900-1.100 for 87.9% of the analytes. Slopes for amylase, tobramycin and urine amylase were <0.8; the slope for lipase was >1.5, due to known methodology or standardization differences. Consequently, reference ranges of amylase, urine amylase and lipase required only minor or no modification. CONCLUSION The four AU5822 analyzers independently evaluated at three sites showed consistent precision, linearity, and correlation results. Since installations, the test results had been well received by clinicians from all three institutions.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of NGAL Test™, a fully-automated neutrophil gelatinase-associated lipocalin (NGAL) immunoassay on Beckman Coulter AU 5822.

BACKGROUND The neutrophil gelatinase associated lipocalin (NGAL) has been identified as the most promising biomarker of acute kidney injury (AKI). This study was aimed to evaluate a NGAL immunoassay on Beckman Coulter AU 5822. METHODS NGAL Test™ (BioPorto Diagnostics A/S) is a particle-enhanced turbidimetric immunoassay. The within-and between-run imprecision were assessed on three urine samp...

متن کامل

Analytical Evaluation of the Clinical Chemistry Analyzer AU 480 Beckman Coulter

Background: Method verification is a one-time process to determine performance characteristics before a test system is utilized for patient testing. Objective: To evaluate the analytical performance of five analytes-glucose (glu), cholesterol (chol), creatinine (crea), aspartate aminotransferase, (AST) and alanine aminotransferase (ALT) on AU 480 Beckman Coulter clinical chemistry analyzer. Met...

متن کامل

Laboratory evaluation of the Beckman Synchron CX3 clinical chemistry analyzer.

In this evaluation of the Beckman Synchron CX3, the multi-analyte clinical chemistry analyzer exhibited high precision, good linearity, and no carryover for each of the eight analytes measured. Results obtained correlated well with those produced by our routine instrumentation (Beckman Astra, Varian atomic absorption spectrophotometer). The instrument can process up to 75 samples per hour (600 ...

متن کامل

An Evaluation of the AcT 5diff Cap Pierce Hematology Analyzer

Staffing constraints and cross-training of laboratory staff have made it imperative that we choose laboratory instruments that not only are user friendly and easy to use but also improve the efficiency of our current systems. Therefore, evaluations of any instrument should also incorporate a component that examines whether workflow can be improved by the use of the instrument being evaluated. I...

متن کامل

Outcome validation of the Beckman Coulter access analyzer in a second-trimester Down syndrome serum screening application.

BACKGROUND Mid-trimester maternal serum alpha-fetoprotein (AFP) and unconjugated estriol (uE3) are 30% lower and human chorionic gonadotropin (hCG) is twofold higher in Down syndrome pregnancies compared with unaffected pregnancies. In maternal serum screening, patient-specific risks are calculated using published gaussian frequency distribution parameters for these three markers obtained with ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical biochemistry

دوره 48 13-14  شماره 

صفحات  -

تاریخ انتشار 2015