Unilateral magnetic stimulation of the phrenic nerve.

نویسندگان

  • G H Mills
  • D Kyroussis
  • C H Hamnegard
  • S Wragg
  • J Moxham
  • M Green
چکیده

BACKGROUND Electrical stimulation of the phrenic nerve is a useful non-volitional method of assessing diaphragm contractility. During the assessment of hemidiaphragm contractility with electrical stimulation, low twitch transdiaphragmatic pressures may result from difficulty in locating and stimulating the phrenic nerve. Cervical magnetic stimulation overcomes some of these problems, but this technique may not be absolutely specific and does not allow the contractility of one hemidiaphragm to be assessed. This study assesses both the best means of producing supramaximal unilateral magnetic phrenic stimulation and its reproducibility. This technique is then applied to patients. METHODS The ability of four different magnetic coils to produce unilateral phrenic stimulation in five normal subjects was assessed from twitch transdiaphragmatic pressure (TwPDI) measurements and diaphragmatic electromyogram (EMG) recordings. The results from magnetic stimulation were compared with those from electrical stimulation. To determine whether the magnetic field affects the contralateral phrenic nerve as well as the intended phrenic nerve, EMG recordings from each hemidiaphragm were compared during stimulation on the same side and the opposite side relative to the recording electrodes. The EMG recordings were made from skin surface electrodes in five normal subjects and from needle electrodes placed in the diaphragm during cardiac surgery in six patients. Similarly, the direction of hemidiaphragm movement was evaluated by ultrasonography. To determine the usefulness of the technique in patients the 43 mm mean diameter double coil was used in 54 patients referred for assessment of possible respiratory muscle weakness. These results were compared with unilateral electrical phrenic stimulation, maximum sniff PDI, and TwPDI during cervical magnetic stimulation. RESULTS In the five normal subjects supramaximal stimulation was established for eight out of 10 phrenic nerves with the 43 mm double coil. Supramaximal unilateral magnetic stimulation produced a higher TwPDI than electrical stimulation (mean (SD) 13.4 (2.5) cm H2O with 35 mm coil; 14.1 (3.8) cm H2O with 43 mm coil; 10.0 (1.7) cm H2O with electrical stimulation). Spread of the magnetic field to the opposite phrenic nerve produced a small amplitude contralateral diaphragm EMG measured from skin surface electrodes which reached a mean of 15% of the maximum EMG amplitude produced by ipsilateral stimulation. Similarly, in six patients with EMG activity recorded directly from needle electrodes, the contralateral spread of the magnetic field produced EMG activity up to a mean of 3% and a maximum of 6% of that seen with ipsilateral stimulation. Unilateral magnetic stimulation of the phrenic nerve was rapidly achieved and well tolerated. In the 54 patients unilateral magnetic TwPDI was more closely related than unilateral electrical TwPDI to transdiaphragmatic pressure produced during maximum sniffs and cervical magnetic stimulation. Unilateral magnetic stimulation eliminated the problem of producing a falsely low TwPDI because of technical difficulties in locating and adequately stimulating the nerve. Eight patients with unilateral phrenic nerve paresis, as indicated by a unilaterally elevated hemidiaphragm on a chest radiograph and maximum sniff PDI consistent with hemidiaphragm weakness, were all accurately identified by unilateral magnetic stimulation. CONCLUSIONS Unilateral magnetic phrenic nerve stimulation is easy to apply and is a reproducible technique in the assessment of hemidiaphragm contractility. It is well tolerated and allows hemidiaphragm contractility to be rapidly and reliably assessed because precise positioning of the coils is not necessary. This may be particularly useful in patients. In addition, the anterolateral positioning of the coil allows the use of the magnet in the supine patient such as in the operating theatre or intensive care unit.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of diaphragm paralysis with oesophageal electromyography and unilateral magnetic phrenic nerve stimulation.

The purpose of this study was to establish a sensitive and reliable method of diagnosing diaphragm paralysis by recording the diaphragm compound muscle action potential (CMAP) using a multipair oesophageal electrode and unilateral magnetic phrenic nerve stimulation. An oesophageal electrode catheter was designed containing six coils (1 cm wide and 3 cm apart), creating an array of four sequenti...

متن کامل

Diaphragm electromyogram measured with unilateral magnetic stimulation.

The purpose of this study was to establish the phrenic nerve conduction time (PNCT) for magnetic stimulation and further assess the relatively new technique of anterior unilateral magnetic stimulation (UMS) of the phrenic nerves in evaluating the diaphragm electromyogram (EMG). An oesophageal electrode was used to record the diaphragm compound muscle action potential (CMAP) elicited by supramax...

متن کامل

Spontaneous recovery of diaphragmatic strength in unilateral diaphragmatic paralysis.

The aim of the present study was to evaluate diaphragmatic strength in patients with unilateral diaphragmatic paralysis and to determine whether patients with recent diaphragm paralysis develop lower inspiratory pressure than patients with longstanding diaphragmatic paralysis. Twenty patients (16 men and 4 women, 62+/-12 years) and six control subjects were included (4 men and 2 women, 53+/-15 ...

متن کامل

Passive stretch of the diaphragm following unilateral phrenic nerve stimulation.

MASMOUDI et al. [1] reported an exciting pilot study on the beneficial effects of unilateral phrenic nerve stimulation on diaphragm muscle trophicity and structure in mechanically ventilated sheep. They observed that, during 72 h of mechanical ventilation, stimulation sessions of 30 min at 4-h intervals attenuated the development of muscle fibre atrophy in the stimulated hemidiaphragm. Fibres f...

متن کامل

Determinants of diaphragm motion in unilateral diaphragmatic paralysis.

Cranial displacement of a hemidiaphragm during sniffs is a cardinal sign of unilateral diaphragmatic paralysis in clinical practice. However, we have recently observed that isolated stimulation of one phrenic nerve in dogs causes the contralateral (inactive) hemidiaphragm to move caudally. In the present study, therefore, we tested the idea that, in unilateral diaphragmatic paralysis, the patte...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Thorax

دوره 50 11  شماره 

صفحات  -

تاریخ انتشار 1995