Diurnal variations in human corneal thickness.

نویسندگان

  • C L Harper
  • M E Boulton
  • D Bennett
  • B Marcyniuk
  • J H Jarvis-Evans
  • A B Tullo
  • A E Ridgway
چکیده

AIM To elucidate the diurnal variation in human corneal thickness over a 48 hour period. METHOD Changes in central corneal thickness were monitored in eight healthy subjects (four male, four female) aged between 10 and 63 years using an ultrasonic pachymeter. Measurements were made over a 48 hour period-immediately before sleep, immediately upon waking and at 15, 30, 45 minutes, 1, 1.5, 2, 2.5, 3 hours, and at 2 hour intervals thereafter throughout the remainder of each day. RESULTS The mean corneal thickness for the group (SD) was 546 (14) microns, with a mean overnight increase of 5.5% (2.9%) (range 1.9-12.6%) and a maximum diurnal increase of 7.2% (2.8%) (range 2.1-14.3%). Individual differences in the extent of diurnal and overnight variation occurred within the group. For three subjects, the first reading taken on waking was not the highest and corneal thickness continued to increase. CONCLUSION These data confirm an increase of corneal thickness during sleep, but also reveal considerable variation during waking hours. Thus, the overnight changes in corneal thickness are not truly representative of diurnal variations in human corneal thickness and, in fact, much greater diurnal variation occurs than the 3.0-4.4% previously reported.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

[Diurnal variations of central and paracentral corneal thickness and curvature].

OBJECTIVE Corneal topography and thickness has clinical importance in contact lens fitting and refractive surgery, however repeated measurement of corneal thickness and curvature is complicated by the natural phenomenon of diurnal variation. Our aim was determine diurnal variations of central and paracentral corneal thickness and curvature over a period of ten hours. MATERIALS AND METHODS Cor...

متن کامل

Diurnal Pattern of Tear Osmolarity and Its Relationship to Corneal Thickness and Deswelling.

PURPOSE To identify the diurnal variations of tear osmolarity (TO) and its relationship with central corneal thickness (CCT) and corneal deswelling over a 14-hour period. METHODS TO and CCT were measured using the TearLab Osmometer and Bioptigen spectral domain optical coherence tomography, respectively, on 38 healthy neophytes (mean age, 21.5 ± 2.2 years). TO and CCT were measured at bedtime...

متن کامل

Repeatability of central and peripheral corneal thickness measurements with the iVue 100 optical coherence tomographer

The cornea is the main refracting surface of the eye1,2,3, comprised of five layers with a sixth corneal layer positioned between the stroma and Descemet’s membrane being proposed.4 The cornea serves many functions which include acting as a convex refracting surface, serving as a barrier against foreign bodies and aiding in stabilisation of the tear film.2 The average central corneal thickness,...

متن کامل

Diurnal Variations in Intraocular Pressure, Central Corneal Thickness, and Macular and Retinal Nerve Fiber Layer Thickness in Diabetics and Normal Individuals

PURPOSE To evaluate diurnal variations in intraocular pressure (IOP), central corneal thickness (CCT), and macular and retinal nerve fiber layer (RNFL) thickness in diabetic patients and normal individuals. METHODS This study included 11 diabetic patients with macular edema and 11 healthy individuals. IOP, CCT, and macular and RNFL thickness were measured every 3 hours on a single day between...

متن کامل

The relationship between diurnal variations in intraocular pressure measurements and central corneal thickness and corneal hysteresis.

PURPOSE To examine the relationship between office-hour changes in IOP, measured with the Goldmann applanation tonometer (GAT) and dynamic contour tonometer (DCT), and the corneal characteristics central corneal thickness (CCT) and corneal hysteresis (CH). METHODS Sixty-two eyes of 62 untreated normal subjects and patients with untreated glaucoma had IOP measurements performed with the GAT (m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 80 12  شماره 

صفحات  -

تاریخ انتشار 1996