Dietary intake of PCDD/Fs and dioxin-like PCBs of the Belgian population.

نویسندگان

  • I Windal
  • S Vandevijvere
  • M Maleki
  • S Goscinny
  • C Vinkx
  • J F Focant
  • G Eppe
  • V Hanot
  • J Van Loco
چکیده

The World Health Organization recommends assessing human exposure to contaminants on a regular basis. In order to assess the current dietary exposure of the Belgian adult population to PCDD/Fs and dioxin-like PCBs and to update exposure estimates of 2000-2001, a total diet study was designed. The mean dietary intake of PCDD/Fs and dioxin-like PCBs in the Belgian adult population in 2008 was estimated to be 0.72pgTEQkgbw(-1)d(-1) (middle bound concentrations, TEF of 1998) based on occurrence data of 2008 and national food consumption data of 2004. This value is clearly below the Tolerable Weekly Intake (TWI) of 14pgTEQkgbw(-1)week(-1) set by the Scientific Committee on Food of the European Commission and below the provisional tolerable monthly intake of 70pgTEQkgbw(-1)month(-1) set by the Joint FAO/WHO Expert Committee on Food Additives. Considering the cumulative distribution, the intake was less than 1pgTEQkgbw(-1)d(-1) for more than 80% of the population, and less than 2pgTEQkgbw(-1)d(-1) for the entire population. When using the 2005 TEF instead of the 1998 TEF, the mean dietary intake in the Belgian adult population was estimated to be 0.61pgTEQkgbw(-1)d(-1).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Estimates of Dietary Intake of Polychlorinated Dioxins, Furans, and Biphenyls from Chinese Total Dietary Study

Introduction Polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) and polychlorinated biphenyls (PCBs) are ubiquitous, persistent, lipophilic pollutants in food. Ingestion of contaminated food is the principal way of human exposure to these compounds, Most data about human exposure to PCDD/Fs and dioxin-like PCBs were available from the industrialized countries 2 while the data from de...

متن کامل

Estimation and characterization of PCDD/Fs and dioxin-like PCB emission from secondary zinc and lead metallurgies in China.

Secondary zinc and lead production is addressed as one of the potential sources of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) and dioxin-like polychlorinated biphenyls (dioxin-like PCBs) due to the impurity of the raw material. However, the release inventory of PCDD/Fs and dioxin-like PCBs is very scarce for these secondary nonferrous metallurgies. This study selected typical...

متن کامل

A preliminary investigation on emission of polychlorinated dibenzo-p-dioxins/dibenzofurans and dioxin-like polychlorinated biphenyls from coke plants in China.

Thermal related processes are widely recognized as the main sources of formation and emission of polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDD/Fs) and polychlorinated biphenyls (PCBs). It is well known that, carbonization of coal in coke production involves many thermal reactions at high-temperature. However, there are still no strong evidences to identify coking processes as source of ...

متن کامل

Significant decreasing trend in human dietary exposure to PCDD/PCDFs and PCBs in Catalonia, Spain.

The concentrations of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/PCDFs), and 18 polychlorinated biphenyls (PCBs) were determined in samples of foodstuffs widely consumed by the population of Catalonia, Spain. The dietary intake of PCDD/PCDFs and dioxin-like (DL)-PCBs was subsequently estimated for the population of this Spanish region. These results were compared with those of a ...

متن کامل

Analysis of PCDD/Fs and dioxin-like PCBs in atmospheric deposition samples from the Flemish measurement network: correlation between the CALUX bioassay and GC-HRMS.

Since the CALUX (Chemically Activated LUciferase gene eXpression) bioassay is a fast, sensitive and inexpensive tool for the analysis of a high number of samples, the use of this technique in routine analysis of atmospheric deposition samples may be a valuable alternative for GC-HRMS. In this study, a validated CALUX method was used for the analysis of PCDD/Fs and dioxin-like PCBs in more than ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chemosphere

دوره 79 3  شماره 

صفحات  -

تاریخ انتشار 2010