Single-source chest-abdomen-pelvis cancer staging on a third generation dual-source CT system: comparison of automated tube potential selection to second generation dual-source CT
نویسندگان
چکیده
BACKGROUND Evaluation of latest generation automated attenuation-based tube potential selection (ATPS) impact on image quality and radiation dose in contrast-enhanced chest-abdomen-pelvis computed tomography examinations for gynaecologic cancer staging. METHODS This IRB approved single-centre, observer-blinded retrospective study with a waiver for informed consent included a total of 100 patients with contrast-enhanced chest-abdomen-pelvis CT for gynaecologic cancer staging. All patients were examined with activated ATPS for adaption of tube voltage to body habitus. 50 patients were scanned on a third-generation dual-source CT (DSCT), and another 50 patients on a second-generation DSCT. Predefined image quality setting remained stable between both groups at 120 kV and a current of 210 Reference mAs. Subjective image quality assessment was performed by two blinded readers independently. Attenuation and image noise were measured in several anatomic structures. Signal-to-noise ratio (SNR) was calculated. For the evaluation of radiation exposure, CT dose index (CTDIvol) values were compared. RESULTS Diagnostic image quality was obtained in all patients. The median CTDIvol (6.1 mGy, range 3.9-22 mGy) was 40 % lower when using the algorithm compared with the previous ATCM protocol (median 10.2 mGy · cm, range 5.8-22.8 mGy). A reduction in potential to 90 kV occurred in 19 cases, a reduction to 100 kV in 23 patients and a reduction to 110 kV in 3 patients of our experimental cohort. These patients received significantly lower radiation exposure compared to the former used protocol. CONCLUSION Latest generation automated ATPS on third-generation DSCT provides good diagnostic image quality in chest-abdomen-pelvis CT while average radiation dose is reduced by 40 % compared to former ATPS protocol on second-generation DSCT.
منابع مشابه
Ultralow-dose chest computed tomography for pulmonary nodule detection: first performance evaluation of single energy scanning with spectral shaping.
PURPOSE The purpose of this study was to evaluate the image quality and sensitivity of ultralow radiation dose single-energy computed tomography (CT) with tin filtration for spectral shaping and iterative reconstructions for the detection of pulmonary nodules in a phantom setting. METHODS Single-energy CT was performed using third-generation dual-source CT (SOMATOM Force; 2 × 192 slices) at 7...
متن کاملChest-abdomen-pelvis CT for staging in cancer patients: dose effectiveness and image quality using automated attenuation-based tube potential selection
BACKGROUND Evaluation of automated attenuation-based tube potential selection and its impact on image quality and radiation dose in CT (computed tomography) examinations for cancer staging. METHODS A total of 110 (59 men, 51 women) patients underwent chest-abdomen-pelvis CT examinations; 55 using a fixed tube potential of 120 kV/current of 210 Reference mAs (using CareDose4D), and 55 using au...
متن کاملLocal Diagnostic Reference Levels for Common Computed Tomography Procedures at a Tertiary Hospital in South Africa
Introduction: An operational computed tomography (CT) scanner is a major source of human exposure to ionizing radiation. Exposure increases the risk of cancer and aplastic anaemia. All radiation exposures should be justified and optimized to meet the clinical objective. In order to avoid the administration of excessive radiation dose to patients, diagnostic reference l...
متن کاملایمنی و عملکرد سی تی اسکن dual-source در مقایسه با سی تی اسکن single-source و آنژیوگرافی مرسوم در تشخیص بیماری های عروق کرونر قلب(مطالعه مروری نظام مند)
Background: The aim of this study is to explore the safety and diagnostic performance of dual-source CT scan in comparison with single source CT scan and conventional angiography in patients with coronary heart diseases.Materials and methods: A systematic review was performed using CRD standard methods. The Cochrane Library, MEDLINE, EMBASE، Google Scholar and TRIP were searched up to April 200...
متن کاملDual-energy CT in colorectal cancers: beyond the density measurements.
I read with interest the article by Özdeniz et al. (1), on dual-source dual-energy computed tomography (DECT) to differentiate fecal matter from neoplasm. The study was well done and was based on density measurements in iodine maps and virtual unenhanced images. I would like to add a few points to the discussion. The main advantage of DECT is material decomposition and the relative iodine conce...
متن کامل