Inflammatory Pseudotumor Complicated by Recurrent Dislocations after Revision Total Hip Arthroplasty

نویسندگان

  • John Ryan Quinn
  • Jason Lee
  • Ran Schwarzkopf
چکیده

A 71-year-old female with a history of right total hip arthroplasty presented with an enlarging pseudotumor. Pseudotumor is a known complication following metal-on-metal and metal-on-conventional polyethylene and metal-on-highly cross-linked polyethylene implants. Revision total hip arthroplasty following resection of pseudotumor has resulted in an increase in incidence of postoperative complications. Despite stable implants, these complications arise from the amount of soft tissue damage combined with the loss of tissue support around the resected hip. Our case is a clear example of a major complication, recurrent dislocation, following resection and revision surgery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pseudotumour Complicated by Implant Loosening One Year After revision Ceramic on Metal Total Hip Arthroplasty: A Case Report

INTRODUCTION Pseudotumor is not an uncommon complication after total hip arthroplasty (THA). This can occur in relationship to different bearing surfaces of head and liner ranging from soft to hard articulation. There is wide spectrum of presentation from asymptomatic to implant failure. CASE REPORT We report a case of pseudotumor formation with acetabular cup aseptic loosening after revision...

متن کامل

A new strategy to reconstruct type III acetabular bone defect associated with inflammatory pseudotumor: combined medial and lateral acetabular bone grafting

RATIONALE Inflammatory pseudotumor has been commonly reported in patients undergoing total hip arthroplasty (THA). PATIENT CONCERNS We reported a patient who had a massive intra-pelvic pseudotumour and acetabular bone defect underwent two-stage revision THA. DIAGNOSES A new surgical strategy for pseudotumor after THA is performed. INTERVENTIONS Thorough debridement intra-pelvic pseudotumo...

متن کامل

Dual-mobility cups for revision due to instability are associated with a low rate of re-revisions due to dislocation

BACKGROUND AND PURPOSE Revision total hip arthroplasty (THA) due to recurrent dislocations is associated with a high risk of persistent instability. We hypothesized that the use of dual-mobility cups would reduce the risk of re-revision due to dislocation after revision THA. PATIENTS AND METHODS 228 THA cup revisions (in 228 patients) performed due to recurrent dislocations and employing a sp...

متن کامل

Growth of an intrapelvic pseudotumor associated with a metal-on-metal total hip arthroplasty after revision arthroplasty causing a femoral nerve neuropathy

The development of pseudotumors is not uncommon with metal-on-metal total hip arthroplasty. Pseudotumors that dissect into the retroperitoneal space can cause symptoms of nerve compression. We describe a case of a 53-year-old male with a metal-on-metal total hip arthroplasty who developed mild symptoms of a femoral nerve neuropathy 6 years postoperatively. Revision arthroplasty to a ceramic-on-...

متن کامل

Flexion reminder device to discourage recurrent posterior dislocation of a total hip replacement: a case report

INTRODUCTION Recurrent dislocation of a total hip replacement prosthesis is a frustrating complication for both the surgeon and the patient. For positional dislocations with no indications for revision surgery, the current best treatment is physiotherapy, the use of abduction braces and avoidance of unsafe hip positions. Abduction braces can be cumbersome and have poor compliance. We report the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2014  شماره 

صفحات  -

تاریخ انتشار 2014