How to define end-diastole and end-systole?: Impact of timing on strain measurements.

نویسندگان

  • Razvan O Mada
  • Peter Lysyansky
  • Ana M Daraban
  • Jürgen Duchenne
  • Jens-Uwe Voigt
چکیده

OBJECTIVES This study aimed to investigate to what extent timing definitions influence strain measurements and which surrogates are reliable and feasible to define end-diastole (ED) and end-systole (ES) during speckle-tracking (STI) analysis. BACKGROUND Current STI-based strain measurements are highly automated. It remains unclear when a particular analysis software defines the zero baseline and the systolic strain measurement position. METHODS A total of 60 subjects (20 healthy volunteers, 20 patients with coronary artery disease, and 20 patients with typical left bundle-branch block) underwent a complete echocardiographic examination. In one-half of them, a real M-mode through the mitral valve was acquired for each electrocardiographic (ECG) lead of the echo machine. Timing of peak R and automatic ECG trigger were compared with mitral valve closure for every electrode. Mitral and aortic valve closure, as observed in the apical 3-chamber view, served as reference for ED and ES. With the use of these references, end-systolic global longitudinal strain (ES-GLS) and end-systolic segmental longitudinal strain (ES-SLS) longitudinal end-systolic strain were measured at baseline and after changing the definition of either ED or ES by ±4 frames. Furthermore, strain and volume curves derived from the same tracking, as well as the Doppler interrogation of the valves, were compared with the references. RESULTS Depending on the selected lead, timing of the ECG-derived time markers changed considerably compared with mitral valve closure. Changing the definition of ED and ES resulted in significantly different ES-GLS and ES-SLS values in all subjects. ES-SLS in dyssynchronous hearts showed the highest sensitivity to timing definition. From all methods, spectral Doppler was the most reliable time marker in all subjects (p > 0.05). CONCLUSIONS Exact temporal definition of ED and ES has a major impact on the accuracy of strain measurements. After direct observation of the valves, Doppler evaluation is the best means for characterizing ED and ES for STI analysis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Limitations of two frame method for displaying regional left ventricular wall motion in man.

Regional abnormalities of left ventricular function are frequently determined from superimposed cavity outlines at end-diastole and end-systole. The timing of end-diastole is standardised with respect to the electrocardiogram, but that of end-systole is undefined, and frequently determined by simple inspection. To examine the effect of variation in the timing of the end-systolic frame on appare...

متن کامل

Timing of high-intensity pulses for myocardial cavitation-enabled therapy

BACKGROUND High-intensity ultrasound pulses intermittently triggered from an ECG signal can interact with circulating contrast agent microbubbles to produce myocardial cavitation microlesions of potential therapeutic value. In this study, the timing of therapy pulses relative to the ECG R wave was investigated to identify the optimal time point for tissue reduction therapy with regard to both t...

متن کامل

Three-dimensional myocardial strains at end-systole and during diastole in the left ventricle of normal humans.

This paper presents the three-dimensional strains in the normal human left ventricle (LV) at end-systole and during diastole. Magnetic resonance tissue tagging was used to measure strain in the left-ventricular heart wall in 10 healthy volunteers aged between 28 and 61 years. The three-dimensional motion was calculated from the displacement of marker points in short- and long-axis cine images, ...

متن کامل

Quantification of myocardial blood flow with cardiovascular magnetic resonance throughout the cardiac cycle

BACKGROUND Myocardial blood flow (MBF) varies throughout the cardiac cycle in response to phasic changes in myocardial tension. The aim of this study was to determine if quantitative myocardial perfusion imaging with cardiovascular magnetic resonance (CMR) can accurately track physiological variations in MBF throughout the cardiac cycle. METHODS 30 healthy volunteers underwent a single stress...

متن کامل

Normal values of M mode echocardiographic measurements of more than 2000 healthy infants and children in central Europe.

OBJECTIVE To obtain normal M mode (one dimensional) echocardiographic values in a substantial sample of normal infants and children. DESIGN Data were obtained over three years from a single centre in central Europe. PATIENTS 2036 healthy infants and children aged one day to 18 years. METHODS In line with recommendations for standardising measurements from M mode echocardiograms, and using...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • JACC. Cardiovascular imaging

دوره 8 2  شماره 

صفحات  -

تاریخ انتشار 2015