The “Magneto View”: A Simple Method for Obtaining Intraoperative Axial Radiographs of the Calcaneus
نویسنده
چکیده
SURGICAL TECHNIQUES THE ORTHOPAEDIC JOURNAL AT HARVARD MEDICAL SCHOOL 116 The “Magneto View”: A Simple Method for Obtaining Intraoperative Axial Radiographs of the Calcaneus
منابع مشابه
Comparison of Bone Mineral Density Measured by Dual X-ray, Axial Dual-energy Photon X-ray Absorptiometry and Laser Absorptiometry of Calcaneus
The objective of this study was to validate the use of bone mineral measurements of the calcaneus bone by dual X-ray and laser (DXL) in a cross-sectional study carried out in an osteoporosis clinic. Measurements of bone mineral density (BMD) at proximal femur and spine were obtained by dual-energy photon X-ray absorptiometry (DEXA). Osteoporosis was defined by a DEXA T-score <-2.5 at the femora...
متن کاملOn the Stability of an Electrostatically-Actuated Functionally Graded Magneto-Electro-Elastic Micro-Beams Under Magneto-Electric Conditions
In this paper, the stability of a functionally graded magneto-electro-elastic (FG-MEE) micro-beam under actuation of electrostatic pressure is studied. For this purpose Euler-Bernoulli beam theory and constitutive relations for magneto-electro-elastic (MEE) materials have been used. We have supposed that material properties vary exponentially along the thickness direction of the micro-beam. Gov...
متن کاملAssessment of Cone-Beam Computed Tomography (CBCT) Findings in Facial Asymmetric Patients
Introduction: Due to the complexity of facial asy-mmetry, the diagnosis of different aspects of asymmetry via conventional radiographs is not precise. In this study, we investigated findings of facial asymmetry by using cone- beam computed tomography (CBCT) images. Materials and Methods: In this descriptive study, we evaluated CBCT findings of 18 patients i.e. a group of 14 females and 4 males ...
متن کاملHygrothermal Creep and Stress Redistribution Analysis of Temperature and Moisture Dependent Magneto-Electro-Elastic Hollow Sphere
In this article, the time-dependent stress redistribution analysis of magneto-electro-elastic (MEE) thick-walled sphere subjected to mechanical, electrical, magnetic and uniform temperature gradient as well as moisture concentration gradient is presented. Combining constitutive equations of MEE with stress-strain relations as well as strain-displacement relations results in obtaining a differen...
متن کاملIntraosseous Lipoma of Calcaneus, Rare Cause of Chronic Calcaneal Pain: A Case Report
Intraosseous lipoma is a rare, benign primary tumor occurring in the bone. Herein, we reported a 45-year-old manwith chronic right posterior heel pain. In this study, the man was treated conservatively due to plantar fasciitis. Duringa one-month follow-up visit, the patient had no symptoms of relief in the right heel pain. Initially, calcaneal X-raywas taken, which revealed an...
متن کامل