A Mdler polarimeter for high energy electron beams

نویسندگان

  • G. Mitchell
  • R. Prepost
  • T. Wright
چکیده

A single arm Msller polarimeter used to measure the longitudinal beam polarization of the 48GeV electron beam for SLAC fixed target experiment E-154 is described. The polarimeter utilizes an array of silicon strip detectors and a dipole magnetic spectrometer to detect Msller scattered electrons from magnetized Fe-Co alloy target foils. The details of the foil pol~ization measu~ments and analysis technique are discussed. The high statistical precision of the Ivl&er data and the stability of the SLAC polarized source made precise studies of the systematic errors in the analysis possible. An overall systematic error of 2.7% is assigned to the beam polarization determination.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A M Ller Polarimeter for High Energy Electron Beams

A single arm M ller polarimeter used to measure the longitudinal beam polarization of the 48 GeV electron beam for SLAC xed target experiment E{154 is described. The polarimeter utilizes an array of silicon strip detectors and a dipole magnetic spectrometer to detect M ller scattered electrons from magnetized Fe-Co alloy target foils. The details of the foil polarization measurements and analys...

متن کامل

Møller Scattering Polarimetry for High Energy e+e− Linear Colliders

The general features of the Møller scattering and its use as an electron polarimeter are described and studied in view of the planned future high energy ee linear colliders. In particular the study concentrates on the TESLA collider which may operate with longitudinal polarised beams at a centre of mass energy of the order of 0.5 TeV with a luminosity of about L = 10 cmsec.

متن کامل

Design of polarized-positron generation system

We have proposed a new method of generating highly polarized positrons through Compton scattering of polarized laser lights o! relativistic electron beams and successive pair creation. To realize high-luminosity laser}electron collisions, we constructed a specially designed chamber which equips o!-axis parabolic mirrors with a through hole at the center. This mirror achieves strong focusing of ...

متن کامل

Low-Energy Deuteron Polarimeter

We built a Low Energy Deuteron Polarimeter (LDP) which measures the spin-polarization of deuteron beams in the energy range of 25 to 80 keV. The LDP works by measuring azimuthal asymmetries in the D(~ d, n)He reaction at θlab = 90 ◦ and comparing them to analyzing powers. We built this polarimeter for two reasons. Firstly, to crosscheck other polarimeters at KVI (LSP and IBP). Secondly to test ...

متن کامل

Polk - ization at SLC * MORRIS

The SLAC Linear Collider has been designed to readily accomodate polarized electron beams. Considerable effort has been made to implement a polarized source, a spin rotation system, and a system to monitor the beam polarization. Nearly all major components have been fabricated. At the current time, severa1 source and polarimeter components have been installed. The installation and commissioning...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1997