Use of Wagner cementless self-locking stems for massive bone loss in hip arthroplasty.

نویسنده

  • S R Lyu
چکیده

OBJECTIVE To assess the use of Wagner cementless self-locking stems for massive bone loss in hip arthroplasty. METHODS 22 patients with severe proximal femoral bone loss either due to prosthetic loosening or comminuted fracture were treated by Wagner cementless self-locking revision stems between November 1993 and June 1995. RESULTS Radiographic evidence of early bony incorporation was found by 1 month in most cases. At a mean follow-up of 7.1 years, the mean Harris hip score increased from 30 to 84 points. It was less than 80 points in 4 patients, 2 of whom experienced severe thigh pain due to marked progressive subsidence of the stems (by 13 mm and 20 mm), which were revised 2 and 3 years later respectively. CONCLUSION Implantation of a Wagner cementless self-locking revision stem provided satisfactory results for 82% of patients. Hence, in some difficult conditions, this device is a good choice of management.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cementless Hip Arthroplasty in Southern Iran, Midterm Outcome and Comparison of Two Designs

Background: Cementless hip prosthesis was designed to provide biologic fixation, without the use of cement. The second generation components have shown more reliable bone ingrowths and survival rates. We are reporting a midterm result of two designs of cementless prosthesis in a unique culture with different social habits and expectations.Methods: 52 primary cementless total hip arthroplasty in...

متن کامل

Total Hip Replacement Revision in a Single Brand Small Cementless Stem – Our Experience after the Findings of the National Joint Registry

Background: Cementless total hip replacement is the common THR performed in England, Wales, Northern Irelandand the Isle of Man. The Corail stem is the most popular cementless implant and has a ODEP 10A rating. Review ofits performance in the registry identified an increase rate of revision amongst the smaller stem sizes. However, claritywas not provided on the explanation for this finding. We ...

متن کامل

The modern, hybrid total hip arthroplasty for primary osteoarthritis at the Hospital for Special Surgery.

We describe our technique and rationale using hybrid fixation for primary total hip arthroplasty (THA) at the Hospital for Special Surgery. Modern uncemented acetabular components have few screw holes, or no holes, polished inner surfaces, improved locking mechanisms, and maximised thickness and shell-liner conformity. Uncemented sockets can be combined with highly cross-linked polyethylene lin...

متن کامل

Bone density study of the proximal femur after hip arthroplasty with porous-coated implants

Progressive loss of bone mineral density around the femora! component of total hip replacement continues to pose a threat to long term prosthetic survival. A linear study was undertaken to measure bone mineral density on a monthly basis following total hip arthroplasty in 11 male patients. The opposite femur was used as the control measurement. Bone mineral density was unchanged at two mo...

متن کامل

Comparison of Specific Femoral Short Stems and Conventional-Length Stems in Primary Cementless Total Hip Arthroplasty.

There are several reported disadvantages with conventional-length femoral stems in cementless total hip arthroplasty (THA). Therefore, various efforts have been made to develop a specific femoral short stem to improve physiologic bone remodeling at the femoral aspect of a cementless THA. However, there are potential disadvantages with specific femoral short stems, such as malalignment, inadvert...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of orthopaedic surgery

دوره 11 1  شماره 

صفحات  -

تاریخ انتشار 2003