Investigation of interfering ions effect on a gadolinium(III) PVC membrane sensor
نویسنده
چکیده
A PVC-membrane ion-selective electrode was constructed for quantitative monitoring of gadolinium(III) ion based on 3-methyl-1H-1,2,4-triazole-5-ylhydrosufide (MTY) as an ion carrier. The electrode performance includes a Nernstian slope of 19.8 ± 0.4 mV per decade across a wide concentration range between 1.0 × 10 and 1.0 × 10 M and a detection limit of 7.3 × 10 M. The best performance was obtained with a membrane composition of 30% poly(vinyl chloride), 66% nitrobenzene (NB), 2% sodium tetraphenyl borate (NaTPB) and 2% MTY. This sensor shows very good selectivity and sensitivity towards gadolinium ion over a wide variety of cations, including alkali, alkaline earth, transition and heavy metal ions. The sensor revealed a great enhancement in selectivity coefficients for gadolinium ions, in comparison to the previously reported gadolinium sensors. For testing applicability of the sensor in real sample analysis, it was successfully applied to the F ions determination in some mouth washing
منابع مشابه
Preparation and Application of Al3+ - Sensor Based On (2Z) — Methyl 2 — ((z) (p-tolylimino) -3-Ethyl —4-0xothiazolidin —5— Ylidene Acetate in PVC Matrix
Al3+-Potentiometric sensor, based on (2Z) -methyl 2- ((z) (p-tolylimino)-3-ethyl -4-oxothiazolidin -5- ylidene) Acetate (MTEOY) as a neutral ionophore, was successfully developed for the detectionof Al3+ in aqueous solutions. The electrode responds to Al3+ ion with a sensitivity of 19.8 ± 0.1 mV/decade over the range 1.0 x 10-8- 1.0 x 10-1 mol LT' and in a pH range of 3.0-9.0. The electrodeshow...
متن کاملPVC based 4,13-didecyl-1,7,10,16-tetraoxa-4,13-diazacyclooctadecane electrode for Cerium (III) ions
A new polyvinyl choloride (PVC) membrane sensor for cerium (III) was prepared based on 4,13-didecyl-1,7,10,16-tetraoxa-4,13-diazacyclooctadecane (kryptofix22DD) as an ionophore. The sensor exhibites a linear concentration range of 1.0×10-6 to 1.0×10-1 M, with a Nernstian slope of 18.0±1.0 mV/decade, and a detection limit of 9.7×10-7 M. It has a fast response tim...
متن کاملPotassium-Selective Membrane Sensor Based on Two Recently Synthesized Poly(oxyethylene) Derivatives
Two poly(oxyethylene) derivatives 1.10-bis(2'-benzoic acid)-1,4,7,1-tetradecane (L1) and 1,7-bis(2'-benzoic acid)-1,4,7-trioxaheptane (L2) were used as suitable ionophores for the preparation of potassium-selective PVC-membrane electrodes. The resulting electrodes based on L1 and L2 exhibit linear responses to the activity of K+ ions within the concentration ranges of 3.1<em...
متن کاملLanthanum(III) Ion Selective Electrode Based on a New Ionophore
A PVC membrane electrode based on 1-[({[(butylsulfunyl)carbothioyl]disulfanyl} carbothioyl)sulfanyl]butane as a suitable ion carrier for determination of lanthanum(III) ion was prepared. This electrode revealedsuch a good selectivity toward La3+ ion over a wide variety of other metal ions. Some experimental parametersuch as membrane composition, nature, and amount of plasticizer, the amount of ...
متن کاملChromium(III) ion selective electrode based on 2H-1,4-benzothioazine-2,3(4H)dione dioxime as a neutral carrier
A poly(vinyl chloride) membrane based on a new a-dioxime derivative as membrane carrier was prepared andinvestigated as a Cr(III) selective electrode. The electrode exhibits a good potentiometric response for Cr(III)over a wide concentration range 1.0 x 10-6 to 1.0 x 10-1 M with a slope 19.5+0.5 mV/decade and low detectionlimit of 8.9 x 10-7 M. It has a fast response time < 15 s. The best perfo...