The consistency of Fletcher-Suit applicator geometry and of the rectal probe’s position in high dose rate brachytherapy treatment fraction of cervix carcinoma
نویسنده
چکیده
PURPOSE The dose values computed with the treatment planning system and the in vivo dose measurements with semiconductor detectors in rectum during the high dose rate brachytherapy treatment fraction of the cervix carcinoma are occasionally significantly different. We've investigated the consistency of the Fletcher-Suit applicator geometry and the in vivo rectal probe's position stability during the high dose rate brachytherapy treatment fraction. MATERIAL AND METHODS The patient lied in a lithotomic position during a biplane reconstruction images, throughout the treatment planning and dose administration. We obtained post-treatment reconstruction images and prepared a post-treatment plan. The amount of 14 treatment fractions of 10 patients were considered in the study. Two methods were applied: evaluation of the difference of reconstructed pre-treatment and post-treatment applicator points and rectal probe's detectors being relevant to the co-ordinate system fixed to the applicator, and estimation of applicators and rectal probe's reallocation with respect to the pelvic bones with registration of pre- and post-treatment reconstruction images. RESULTS We've experienced good consistency in the Fletcher-Suit applicator geometry in all treatment fractions. 70% of them presented small variation in the rectal probe's position, while the rest showed significant shift in the applicator or rectal probe's position with regard to the pelvic bones.
منابع مشابه
Study of dosimetric and spatial variations due to applicator positioning during inter-fraction high-dose rate brachytherapy in the treatment of carcinoma of the cervix: A three dimensional dosimetric analysis
Background: This study evaluates dosimetric and spatial variations in inter–fraction applicator positioning in high dose rate (HDR) brachytherapy. Materials and Methods: This study includes 25 retrospective patients of carcinoma of the cervix. Each patient received 5 fractions of HDR intracavitary brachytherapy. High Risk-Clinical Target Volume (HR-CTV) were drawn on CT images. First impl...
متن کاملDosimetric evaluation of a newly designed low dose rate brachytherapy applicator for treatment of cervical cancer with extension into the lower vagina
Currently, patients having cervical cancer with extension into the lower vagina are being treated with a combination of the Fletcher-Suit applicator, which treats the cervix, and a vaginal cylinder, which treats the lower vagina. With this method, patients receive two separate implants-a procedure that creates greater uncertainty in the dose distribution and unnecessary patient inconvenience. T...
متن کاملThe usefulness of fleet rectal enemas on high-dose-rate intracavitary cervical cancer brachytherapy. A prospective trial
PURPOSE To evaluate the effects of rectal enemas on rectal doses during radical high-dose-rate (HDR) intracavitary cervical brachytherapy (BT). MATERIAL AND METHODS Twenty patients suffering from cervical cancer and treated with external beam radiotherapy and HDR-BT were included in a prospective trial. The first brachytherapy fraction was considered the basal status, and patients were instru...
متن کاملApplicator Attenuation Effect on Dose Calculations of Esophageal High-Dose Rate Brachytherapy Using EDR2 Film
Introduction Interaluminal brachytherapy is one of the important methods of esophageal cancer treatment. The effect of applicator attenuation is not considered in dose calculation method released by AAPM-TG43. In this study, the effect of High-Dose Rate (HDR) brachytherapy esophageal applicator on dose distribution was surveyed in HDR brachytherapy. Materials and Methods A cylindrical PMMA phan...
متن کاملA comparison of dose distribution from Manchester-style and Fletcher-style intracavitary brachytherapy applicator systems in cervical cancer
PURPOSE During intracavitary brachytherapy (ICBT) for cervical cancer, the choice of applicator system remains rather arbitrary. However, as the applicator geometry may play an important role in dose distribution, thereby improving the therapeutic ratio, this study was conducted to compare the Manchester-style and Fletcher-style applicator systems. MATERIAL AND METHODS After completion of EBR...