Laser Acupuncture and Local Laser Therapy in Veterinary Medicine with Overview of Applied Laser Types and Clinical Uses

نویسنده

  • Uwe Petermann
چکیده

Wang Y1, Zhang Y, Wang W, Cao Y, Han JS. Effects of synchronous or asynchronous electroacupuncture stimulation with low versus high frequency on spinal opioid release and tail flick nociception. Exp Neurol. 2005 Mar;192(1):156-62. Electroacupuncture stimulation (EAS) is known to change brain neurotransmitter release. In the present study, we investigated the effects of synchronous or asynchronous electroacupuncture stimulation with low versus high frequency on spinal opioid release and tail flick nociception. Rats were given “2/100 Hz” EAS, which stands for an asynchronous mode of stimulation, in which 2 Hz was alternated with 100 Hz, each lasting for 3 s, or “(2 + 100) Hz” EAS, a mode of stimulation in which 2 Hz stimulation was applied to the left hind leg simultaneously with 100 Hz stimulation on the right hind leg. The rats were subjected to the same total number of electrical stimulations in these two modes. Results were as follows: (1) 2/100 Hz EAS was 40% more potent than (2 + 100) Hz EAS (P < 0.01) in producing an anti-nociceptive effect. (2) Intrathecal (i.t.) injection of the mu-opioid receptor antagonist D-Phe-Cys-Tyr-D-Trp-Orn-Thr-Pen-Thr amide (CTOP) blocked in a dose-dependent manner the anti-nociceptive effect produced by 2/100 Hz EAS but not by (2 + 100) Hz EAS, whereas i.t. injection of the kappa-opioid receptor antagonist norbinaltorphimide (Nor-BNI) blocked the anti-nociceptive effect induced by both modes of EAS. (3) I.t. injection of endomorphin-2 antiserum blocked in a dose-dependent manner the anti-nociceptive effect of 2/100 Hz EAS but not that of (2 + 100) Hz EAS, whereas i.t. injection of dynorphin antiserum blocked the anti-nociceptive effect induced by both modes of stimulation. (4) 2/100 Hz EAS increased the release of both endomorphin-2 and dynorphin, whereas (2 + 100) Hz EAS increased the release of dynorphin but not of endmorphin-2. We conclude that the more potent anti-nociceptive effect induced by 2/100 Hz EAS, as compared with that of (2 + 100) Hz EAS, was due, at least partly, to the synergistic interaction of endomorphin-2 and dynorphin in rat spinal cord.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of Local Transplantation of Autologous Bone Marrow Mesenchymal Stem Cells in Combination with Low Level Laser Therapy in Repair of Experimental Acute Spinal Cord Injury in Rats

Objective- The aim of this study was to demonstrate the efficacy MSCs transplantation in combination with low level laser irradiation (low level laser irradiation) in repair of experimental acute spinal cord injury. Design- Experimental study. Animals- 28 adult male Wistar Rats. Procedures- A ballon- compression technique was used to produce an injury at the T8-T9 level of spi...

متن کامل

The effect of low power LASER acupuncture on experimental pain threshold in normal subjects

Background: Acupuncture is an indispensable part of traditional Chinese medicine for relief of pain. The purpose of this study was the immediate & latent of low power LASER Ga-Al-As irradiation applied to acupuncture points on experimental pain threshold. Methods: This quasi-experimental study was conducted on seventy adult women ranging from 20 to 40 years old assigned randomly into two groups...

متن کامل

An overview of therapeutic applications of ultrasound based on synergetic effects with gold nanoparticles and laser excitation

Acoustic cavitation which occurs at high intensities of ultrasound waves can be fatal for tumor cells. The existence of dissolved gases and also the presence of nanoparticles (NPs) in a liquid, irradiated by ultrasound, decrease the acoustic cavitation onset threshold and the resulting bubbles collapse. On the other hand, due to unique capabilities and optical properties of gold nanoparticles (...

متن کامل

Cumulative Clinical Evaluation of Transcutaneous Blood Laser Irradiation on Hemodynamic Changes in Anesthesia of Dogs

Objectives-The aims of this study were evaluation the effects of blood laser irradiation on hemodynamic parameters, the amount of anesthetic drugs in maintenance of anesthesia and duration of recovery. Animals- Fifteen mixed breed dogs Procedures- dogs (25.0 ± 3.6 kg) were divided into three groups (n=5). The group I was acted as control and received only cold laser. The group II was premedicat...

متن کامل

Evaluation of Low Level Laser Effects on Epidural Anestesia in Horse

Abstract Objective: To evaluate and compare the analgesic effects of caudal epidural administration of lidocaine (LIDO), caudal laser radiation and epidural lidocaine plus laser radiation in horses. Study design: A blinded, randomized, prospective, experimental cross-over study. Animals: Five healthy horses, 15.7 +/- 4.9 years of age, weighing 240 +/- 37 kg. Methods: The...

متن کامل

Computed Tomographic Evaluation of Tooth Growth in Response to Diode Laser Irradiation in Rabbits

Background: While many dental procedures induce pulpal damage by increase the temperature, this study was established to evaluate the thermally effect of different laser methods on pulp, oral soft and hard tissues. Objectives: In this study, laser irradiation applied to measure how increased in power output can influence on dental pulp by using CT images. Methods: Ten adult New Zealand white ra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016