Highly accelerated 7 T prostate imaging using parallel imaging
نویسندگان
چکیده
Introduction Due to stronger signal attenuation and high SAR levels, prostate imaging at 7 Tesla is a challenging procedure. Nevertheless, it has been demonstrated with various surface coil array designs [1,2,3]. For this work we used an array of single-side adapted dipole antennas [1]. The elements of this array have been designed according to a radiative design principle maximizing the power flow towards the prostate resulting in higher B1 efficiency at depth. With this antenna design the SAR levels can be reduced by a factor of 4 compared to conventional coil designs and the B1 field level in the prostate reaches 10 μT using 8 x 1 kW amplifiers. Consequently, good receive performance of this array is expected as well. On top of that, the short wavelength and the distinct sensitivity patterns of the individual elements promise good parallel imaging performance. To quantify this, we characterized the parallel imaging performance of this array for prostate imaging at 7 Tesla. Materials and methods For all measurements we used a surface array consisting of 8 transceive elements aligned like a belt around the pelvis (figure 1a). Each element consists of a 7 x 4.2 x 14.3 cm dielectric ceramic substrate. At the distal side of the substrate a copper tape dipole antenna is mounted where the length of the legs of the antenna is tuned to support a standing λ/2 wave. The element is fed through a BalUn and a matching network (figure 1b). A reference image was obtained by travelling wave imaging [4] using a SQL antenna (figure 1c, [5]). Spoiled GRE images (TR/TE = 28/1.5 ms, FA = 45°, 2 x 2 x 10 mm, 2D) were obtained using SENSE with a reduction factor varying from 1 to 8. Dynamic noise scans were used to determine the SNR. From these images the SNR in the prostate and the geometry factor distribution were determined for each reduction factor. Results and discussion The SNR in the prostate was determined to be 81, 50, 37 and 19 for reduction factors of 1, 3, 5 and 7 respectively. In figure 2, SENSE images are presented with indicated reduction factors. As we expected, the individual elements have very well separated sensitivity profiles which is reflected by good parallel imaging performance up to a reduction factor of 6. g-Factor distributions show that the SNR penalty is limited, particularly in the prostate. Note that although these results were obtained with spoiled gradient echo sequences, the results apply to any sequence. The reduction in scan time can be traded off with various other parameters. For the clinically relevant T2 weighted TSE imaging, the echo train length can be reduced which will drastically reduce the number of SAR expensive refocusing pulses. As 7T prostate imaging comes with considerable SAR challenges, we particularly foresee potential of using the good parallel imaging performance to reduce SAR levels. But the procedure can also be used to reduce the EPI echo train in DWI. Conclusion In addition to having good transmit efficiency and low SAR levels, the array of single-side adapted dipole antennas also has very good parallel imaging properties. The sensitivity patterns of the individual elements are well separable allowing large reduction factors of up to 6 for prostate imaging. The high acceleration factor can be exploited to significantly accelerate a 7T prostate exam or can be traded off with other sequence parameters. As such, this will boost the clinical feasibility of 7T prostate imaging.
منابع مشابه
Highly-Accelerated First-Pass Cardiac Perfusion MRI Using Compressed Sensing and Parallel Imaging
INTRODUCTION: First-pass cardiac perfusion MRI is a promising modality for the assessment of coronary artery disease. Recently developed dynamic parallel imaging techniques, such as k-t SENSE [1] and k-t GRAPPA [2], can be used to perform up to 10-fold accelerated perfusion imaging by exploiting the difference in coil sensitivities and spatio-temporal correlations. Such techniques can be used t...
متن کاملOptimization of clinical target volume delineation using magnetic resonance spectroscopic imaging (MRSI) in 3D conformal radiotherapy of prostate cancer
Background: For the purpose of individual clinical target volume assessment in radiotherapy of prostate cancer, MRSI was used as a molecular imaging modality with MRI and CT images. Materials and Methods: The images of 20 prostate cancer patients were used in this study. The MR and MRSI images were registered with CT ones using non-rigid registration technique. The CT based planning (BP), CT/MR...
متن کاملبررسی ارزش Diffusion Weighted Imaging در تصاویر MRI برای تشخیص سرطان پروستات
Background: Prostate cancer is the third leading cause of death and is the most common cause of cancer in elderly men. Regarding to the low accuracy of screening methods such as prostate-specific antigen (PSA), Digital Rectal Examination (DRE) and trans rectal ultrasound (TRUS) in detection and localization of tumor, Magnetic Resonance Imaging (MRI) and Diffusion Weighted Imaging (DWI) attracte...
متن کاملEffectiveness of 32-element Surface Coil Array for Accelerated Volume-Targeted Breath-Hold Coronary MRA
Purpose : To compare 12 and 32-element surface coil arrays for highly accelerated coronary magnetic resonance angiography (MRA) using parallel imaging. Materials and Methods : Steady state free precession coronary MRA was performed in 5 healthy volunteers at 1.5 T whole body MR scanner using both 12 and 32-element surface coil arrays. Left anterior descending and right coronary artery data sets...
متن کاملkt SPIRiT for Ultra-Fast Cardiac Cine Imaging with Prospective or Retrospective Cardiac Gating
Introduction: Cardiac cine imaging requires ultra-fast acquisition of high spatiotemporal resolution images within a short breathhold, which is difficult for conventional parallel imaging (PI). Recent progress has increased the achievable acceleration mainly from two perspectives. First, various kt methods [1,2,3] have proven capable of providing reasonable image quality at high acceleration fa...
متن کامل