Automatic estimation and correction of anisotropic magnification distortion in electron microscopes.

نویسندگان

  • Timothy Grant
  • Nikolaus Grigorieff
چکیده

We demonstrate a significant anisotropic magnification distortion, found on an FEI Titan Krios microscope and affecting magnifications commonly used for data acquisition on a Gatan K2 Summit detector. We describe a program (mag_distortion_estimate) to automatically estimate anisotropic magnification distortion from a set of images of a standard gold shadowed diffraction grating. We also describe a program (mag_distortion_correct) to correct for the estimated distortion in collected images. We demonstrate that the distortion present on the Titan Krios microscope limits the resolution of a set of rotavirus VP6 images to ∼7 Å, which increases to ∼3 Å following estimation and correction of the distortion. We also use a 70S ribosome sample to demonstrate that in addition to affecting resolution, magnification distortion can also interfere with the classification of heterogeneous data.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Description and comparison of algorithms for correcting anisotropic magnification in cryo-EM images.

Single particle electron cryomicroscopy (cryo-EM) allows for structures of proteins and protein complexes to be determined from images of non-crystalline specimens. Cryo-EM data analysis requires electron microscope images of randomly oriented ice-embedded protein particles to be rotated and translated to allow for coherent averaging when calculating three-dimensional (3D) structures. Rotation ...

متن کامل

Fully automatic stitching and distortion correction of transmission electron microscope images.

In electron microscopy, a large field of view is commonly captured by taking several images of a sample region and then by stitching these images together. Non-linear lens distortions induced by the electromagnetic lenses of the microscope render a seamless stitching with linear transformations impossible. This problem is aggravated by large CCD cameras, as they are commonly in use nowadays. We...

متن کامل

A practical method to detect and correct for lens distortion in the TEM.

A practical, offline method for experimental detection and correction for projector lens distortion in the transmission electron microscope (TEM) operating in high-resolution (HR) and selected area electron diffraction (SAED) modes is described. Typical TEM works show that, in the simplest case, the distortion transforms on the recording device, which would be a circle into an ellipse. The firs...

متن کامل

Joint denoising and distortion correction of atomic scale scanning transmission electron microscopy images

Nowadays, modern electron microscopes deliver images at atomic scale. The precise atomic structure encodes information about material properties. Thus, an important ingredient in the image analysis is to locate the centers of the atoms shown in micrographs as precisely as possible. Here, we consider scanning transmission electron microscopy (STEM), which acquires data in a rastering pattern, pi...

متن کامل

Software methods for identification and compensation of electron beam vibration in SEM

Periodic image distortions caused by undesirable vibration of the electron beam are well known problem in scanning electron microscopy (SEM). They are usually observable at medium and high scan-rates (few milliseconds per scan-line and less) as a sinusoidal or sawtooth shaped deformation of specimen edges [1]. At low scan-rates the vibration causes a blur of images. Appearance and level of the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of structural biology

دوره 192 2  شماره 

صفحات  -

تاریخ انتشار 2015