Standardization of creatine kinase-MB (CK-MB) mass assays: the use of recombinant CK-MB as a reference material.

نویسندگان

  • R H Christenson
  • H Vaidya
  • Y Landt
  • R S Bauer
  • S F Green
  • F A Apple
  • A Jacob
  • G R Magneson
  • S Nag
  • A H Wu
  • H M Azzazy
چکیده

BACKGROUND The AACC assembled a committee to identify and validate a standard creatine kinase MB isoenzyme (CK-MB) material to improve the comparability of CK-MB mass assays. METHODS Three protocols were used. In protocol I, various CK-MB materials prepared in different matrices were screened as candidate standards. In protocol II, participating manufacturers calibrated their systems with concentrates of human heart CK-MB and then tested 20 patient samples to evaluate calibration bias. In protocol III, participating manufacturers calibrated their immunoassay systems using recombinant CK-MB2 (rCK-MB2) diluted into their respective sample diluents and measured 50 samples. RESULTS Candidate materials showed high recovery in stripped human serum, but bias improved only from 59% to 38%. These data led to the use of human heart CK-MB diluted in each manufacturer's sample diluent. This strategy reduced bias from 31% to 15%. Because human heart CK-MB is difficult to provide, a lyophilized source of CK-MB2 was identified. rCK-MB2 was shown by sodium dodecyl sulfate-polyacrylamide gel electrophoresis, reversed-phase HPLC, intrinsic protein fluorescence, circular dichroism, agarose gel electrophoresis, immunoreactivity studies, high and low temperature stability, and reconstituted stability to be equivalent to human heart CK-MB. Calibration of immunoassay systems with rCK-MB2 added into each respective manufacturer's sample diluent showed a 13% between-manufacturer bias. CONCLUSION Lyophilized rCK-MB2 was determined suitable for use as a reference material for CK-MB mass assays.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Production of recombinant human creatine kinase (r-hCK) isozymes by tandem repeat expression of M and B genes and characterization of r-hCK-MB.

BACKGROUND Serum creatine kinase-MB isoenzyme (CK-MB) is widely used as a marker of myocardial injury. We prepared recombinant human CK (r-hCK) MB isoenzyme and examined its potential for use as a control material for assay of CK-MB in serum. METHODS cDNAs encoding CK-M and CK-B subunits were inserted into the same plasmid vector, followed by transformation of Escherichia coli. The resulting ...

متن کامل

False-Positive Elevation of Creatine Kinase MB Mass Concentrations Caused by Macromolecules in a Patient who Underwent Nephrectomy for Renal Cell Carcinoma

Creatine kinase MB isoform (CK-MB) is a biochemical marker that is used to evaluate patients with suspected acute myocardial infarction. Rapid immunoassays to measure CK-MB mass concentration use various monoclonal anti-CK-MB antibodies, and these have been reported to be highly sensitive, specific, and free of interference [1]. Here, we report the first case of a false-positive CK-MB result (a...

متن کامل

Effects of hemolysis on the assays of serum CK, CK-MB activities and CK-MB (mass), troponin and myoglobin measurements

Aim: The aim of the study was to investigate the effects of in vitro hemolysis on serum creatine kinase and creatine kinase MB isoenzyme activities with creatine kinase MB mass, troponin I and myoglobin measurements. Materials and methods: We prepared serum pools having analyte concentrations at normal and pathological values. Hemolysate was added into serum pools to obtain aliquotes with final...

متن کامل

Immunochemiluminometric assay of creatine kinase MB with a monoclonal antibody to the MB isoenzyme.

Previous two-site immunometric assays for creatine kinase (CK; EC 2.7.3.2) MB isoenzyme have been based on formation of a "sandwich" complex involving CK-MB and antibodies that recognize the CK-MM and the CK-BB isoenzymes. Single-incubation model assays of CK-MB with these antibodies were susceptible to interferences by CK-MM and CK-BB. We produced two anti-CK-MB monoclonal antibodies and studi...

متن کامل

Stratus automated creatine kinase-MB assay evaluated: identification and elimination of falsely increased results associated with a high-molecular-mass form of alkaline phosphatase.

We compared the performance of an automated assay of creatine kinase MB isoenzyme (CK-MB) mass (Stratus) with that of a CK-MB enzymatic assay routinely used at our institutions. Both of these assays use the same CK-MB-specific monoclonal antibody to immunocapture CK-MB, thus providing a direct means of comparing a mass assay with an activity assay. Routine CK-MB measurements for 206 samples wit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 45 9  شماره 

صفحات  -

تاریخ انتشار 1999