Energy Efficient and Lower Capital Cost – an Alternative Data Center Cooling Strategy

نویسندگان

  • Phil Hughes
  • William Tschudi
چکیده

A standard air cooled data center is a rare phenomenon. Generally each one is individually designed, with hundreds of different component combinations. They can also be energy hogs. Cooling system power consumption in older data centers is typically 100% or more of the IT load. While energy efficiency has improved recently and Power Utilization Effectiveness (PUE) values – the ratio of total energy use to the IT equipment energy use of 1.2 and better are being designed, we could be approaching the limit of air system cooling capability. While liquid cooling systems can provide further improvement, previous liquid systems have been too complex, delicate, expensive, and unreliable. This paper describes a novel cooling approach that could provide savings in energy use with lower capital cost. In the first section of this paper we review various ways of cooling with air and demonstrate that the distance of the heat generator to the cold sink plays a large part in the total cooling energy consumption. The logical conclusion is that totally eliminating the air gap between the hot source and the cold sink is highly advantageous. Liquid, with its high heat conveyance is an effective way of achieving this. Much work is being done in order to overcome the deficiencies of liquid cooling systems. In the second section of the paper a sampling of the design strategies being pursued is presented. A description of a “direct touch” cooling system using pumped refrigerant will be discussed in detail. This technology was developed in part under a grant from the California Energy Commission’s Public Interest Energy Research (PIER) program. This alternative cooling system could be simpler to adopt using industry standard servers; it is robust and requires no special training to administer. Above all, it allows extensive standardization. It can reduce both energy consumption and capital expenditure by up to 50% and increase power density up to 100 times. With this technology, it becomes practical to put a small data center in a wiring closet and a petaflop Phil Hughes, Phil Hughes is CEO of Clustered Systems Company, Inc., developer of low cost liquid cooling systems ; William Tschudi, PE, is a program manager at LBNL and an ASHRAE Member computing system in a cubicle. This system is noiseless and virtually room neutral for thermal input. Results from third party testing comparing traditional air cooling and this direct touch system are presented.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Study of Thermostat Impact on Energy Consumption in a Residential Building by Using TRNSYS

The present study investigates the effectiveness of thermostat control strategy in cooling energy consumption in residential buildings. To evaluate the energy consumption, two scenarios including a residential zone with and without the thermostat control system are assumed. The TRNSYS software provides an efficient numerical tool to model and evaluate a cooling system. Furthermore, since solar-...

متن کامل

Thermal Modeling and Analysis of Cloud Data Storage Systems

—An explosive increment of data and a variety of data analysis make it indispensable to lower power and cooling costs of cloud datacenters. To address this issue, we investigate the thermal impact of I/O access patterns on data storage systems. Firstly, we conduct some preliminary experiments to study the thermal behavior of a data storage node. The experimental results show that disks have ig...

متن کامل

Energy Conservation for Servers

Introduction Power management has been thoroughly studied for applications running on battery-powered platforms [3,5]. We take the position that power management is equally important for server environments, where high performance and reliability have traditionally been the most important design and evaluation factors. This position breaks with tradition and argues for considering energy consum...

متن کامل

Virtualization Implementation Model for Cost Effective & Efficient Data Centers

Data centers form a key part of the infrastructure upon which a variety of information technology services are built. They provide the capabilities of centralized repository for storage, management, networking and dissemination of data. With the rapid increase in the capacity and size of data centers, there is a continuous increase in the demand for energy consumption. These data centers not on...

متن کامل

تعیین نقطه کاری بهینه در سیستم تولید همزمان انرژی الکتریکی و گرمایی به همراه مخزن ذخیره گرمایی با استفاده از الگوریتم ژنتیک

Utilization of combined heat and power (CHP) systems that simultaneously fulfill the electrical and heating energy needs is considered as an effective strategy for management of energy demand and consumption. Overall operational efficiency in excess of 70% is made possible, when these systems are utilized, and it is expected that needs for both the demand and supply sides are met even under ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011