For earlier diagnosis of human immunodeficiency virus type 1 (HIV-1) infection, the sensitivities of immune complex transfer enzyme immunoassays for HIV-1 p24 antigen and antibody immunoglobulin G (IgG) to HIV-1 p17 antigen were improved approximately 25- and 90-fold, respectively, over those of the previous immunoassays by performing solid-phase immunoreactions with shaking and increasing the serum sample volumes, and immune complex transfer enzyme immunoassay of antibody IgM to p17 antigen was also performed in the same way as the improved immunoassay of antibody IgG to p17 antigen. By the improved immunoassays, p24 antigen and antibody IgG to p17 antigen were detected earlier in 32 and 53%, respectively, of the HIV-1 seroconversion serum panels tested than before the improvements, and p24 antigen was detected as early as or earlier than HIV-1 RNA by reverse transcriptase-PCR (RT-PCR) in all of the panels tested. In 4 panels out of 19 tested, antibody IgG to p17 antigen or both antibodies IgG and IgM to p17 antigen were detected earlier than p24 antigen and RNA, although the antibody levels declined slightly before their steep increases usually observed after p24 antigen and RNA. Thus, the window period in diagnosis of HIV-1 infection can be shortened by detection of p24 antigen with the improved immunoassay as much as by detection of RNA with RT-PCR and, in some cases, more by detection of antibodies IgG and IgM to p17 antigen with the improved immunoassays than by detections of p24 antigen with the improved immunoassay and RNA with RT-PCR.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cloning, Expression, Purification and Immunoreactivity Analysis of Gag Derived Protein p17 from HIV-1 CRF35 in Fusion with Thioredoxin from Human Subjects

So far, recombinant antigens of HIV-1, the etiologic cause of Acquired Immunodeficiency Syndrome (AIDS), have been widely used for the diagnosis and vaccine development. P17 or the matrix protein formed by the proteolytic cleavage of gag is strongly antigenic and is as conserved and immunogenic as p24. In some cases, antibodies to p17 are more prevalent than antibodies to p24 and the decline in...

متن کامل

Early detection of human immunodeficiency virus type 1-specific B-lymphocyte-derived antibodies in a high-risk population.

Diagnosis of acute human immunodeficiency virus (HIV) infection, a key driver of the HIV epidemic, remains a public health challenge. The PlasmAcute technology offers an opportunity to detect early anti-HIV antibody responses. B lymphocytes (B cells) were isolated from the blood of seronegative miners in South Africa by using the PlasmAcute method. B-cell lysates and paired sera were tested for...

متن کامل

Early detection of antibody to human immunodeficiency virus type 1 by using an antigen conjugate immunoassay correlates with the presence of immunoglobulin M antibody.

Sequential plasma samples obtained from 16 individuals who seroconverted were tested for the presence of antibody to human immunodeficiency virus type 1 (HIV-1) by an antigen conjugate enzyme immunoassay (EIA) and a conventional antibody conjugate assay. In 11 of these individuals, the antigen conjugate assay detected antibody to HIV-1 2 to 11 days (mean, 5.5 days) earlier than the antibody con...

متن کامل

Detection of antibodies to human immunodeficiency virus (HIV) that recognize conformational epitopes of glycoproteins 160 and 41 often allows for early diagnosis of HIV infection.

On the basis of human immunodeficiency virus (HIV) needlestick studies, the time to seroconversion for anti-HIV antibodies is 1-9 months (mean, approximately 2-3 months). However, an earlier marker of an immune response to HIV often occurs-serum anti-HIV antibodies reactive with live HIV-infected cells, termed "early HIV antibodies." The specificities of these antibodies are characterized by th...

متن کامل

Multicenter evaluation of a new, automated enzyme-linked immunoassay for detection of human immunodeficiency virus-specific antibodies and antigen.

A collaborative multicenter study was conducted to evaluate the sensitivity, specificity, and precision of a three-step, fully automated, qualitative microparticle-based enzyme-linked immunoassay (AxSYM HIV Ag/Ab Combo; Abbott Laboratories), designed to simultaneously detect (i). antibodies against human immunodeficiency virus type 1 (HIV-1) and/or type 2 (HIV-2) and (ii). HIV p24 antigen. A si...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical and diagnostic laboratory immunology

دوره 7 6  شماره 

صفحات  -

تاریخ انتشار 2000