Calibration of an InGaAs photodiode at 1300 nm with a cryogenic radiometer and a diode laser
نویسندگان
چکیده
A single-element, windowless InGaAs photodetector has been calibrated against a cryogenic radiometer using a diode-laser source of wavelength 1296.9 nm (standard uncertainty = 0.4 nm). This source differs from the gas lasers usually used with cryogenic radiometers in that the beam has an elliptical profile, is invisible to the naked eye, is not polarized, and is less spatially coherent. We describe the simple adaptations we have made to use this source with the cryogenic radiometer. In particular, we use a fibre-optic delivery system to prepare the beam, and an anti-reflection-coated window to admit the radiation. The relative uncertainty in this method of calibration is estimated to be 0.08 % (1 ). The measured response (0.9752 A/W) differs from that obtained from the existing laboratory scale by 0.08 %.
منابع مشابه
Comparison of Two Cryogenic Radiometers at NIST
Two cryogenic radiometers from NIST, one from the Optical Technology Division and the other from the Optoelectronics Division, were compared at three visible laser wavelengths. For this comparison, each radiometer calibrated two photodiode trap detectors for spectral responsivity. The calibration values for the two trap detectors agreed within the expanded (k = 2) uncertainties. This paper desc...
متن کاملTreatment of lentigines by a novel high power diode laser at 755 nm: a case report
The use of high-power diode laser with a wavelength of 755 nm is an effective and safe method for the correction and partial and/or total elimination of pigmented lesions, specifically solar lentigines. This wavelength has yet not been used in diode lasers to treat solar lentigines. Side effects are the usual ones, including darkening and scab formation. Our patient was a 40-year-old woman of C...
متن کاملComparison the Effect of 810 nm and 940 nm Diode Lasers on Solobacterium Moorei in Vitro
Background and aim: Given the role of Solobacterium moorei in bacteremia, septicemia, oral infections, halitosis, and periodontal diseases and previous research defects considering the important role of laser in comparison with the application of antimicrobial agents, the purpose of this research was to compare the effect of 810nm and 940nm lasers on Solobacterium moorei in vitro situation. Mat...
متن کاملOptical Radiation Measurements Based on Detector Standards
A near-IR radiometer standard with similar performance to silicon trap-detectors has been developed to calibrate detectors and radiometers for absolute spectral power, irradiance, and radiance responsivities between 950 nm and 1650 nm. The new radiometer standard is utilized at the Spectral Irradiance and Radiance Responsivity Calibrations using Uniform Sources (SIRCUS) which is the reference c...
متن کاملDevelopment of a high stability L-band radiometer for ocean salinity measurements
Future sea surface salinity missions will require Lband radiometers to have calibration stabilities of ≤ 0.05 K over 2 days. This research program has focused on determining the optimum radiometer requirements and configuration to achieve this objective. System configuration and component performance have been evaluated with radiometer test beds at both JPL and GSFC. The GSFC testbed uses a cry...
متن کامل