Is determination of creatine kinase-2 after electrophoretic separation accurate?
نویسندگان
چکیده
Since 1991, the Ontario Laboratory Proficiency Testing Program has assessed the analytical performance of creatine kinase (CK; EC 2.7.3.2) isoenzyme-2, using fresh human serum supplemented with purified human CK isoenzymes. In Ontario, the 142 laboratories licensed to analyze CK-2 use a variety of methods: electrophoresis-based, immunoinhibition, and mass assays. During a 1992 survey, duplicate CK-2 samples with different total CK activities showed poorer precision when analyzed after electrophoretic separation than by any other method. A 1993 survey designed to validate these observations conclusively showed that electrophoresis-based assays are subject to a bias proportional to the total CK activity. These survey results were confirmed by studies with selected patients' specimens. We therefore conclude that electrophoresis-based assays may not warrant their reputation as the gold standard for CK isoenzyme measurement.
منابع مشابه
Identification of a 43-kDa polypeptide associated with acetylcholine receptor-enriched membranes as MM creatine kinase.
Creatine kinase isoenzymes from Torpedo californica electric organ, skeletal muscle, and brain were purified and characterized. Torpedo electric organ and skeletal muscle creatine kinase have identical apparent Mr, electrophoretic mobility, and cyanogen bromide fragments. The electrophoretic mobility of the Torpedo creatine kinase was anodal as compared to mammalian MM creatine kinase. No creat...
متن کاملImproved electrophoretic separation of creatine kinase isoenzymes.
Creatine kinase isoenzymes are separated electrophoretically on cellulose acetate, with use of an improved procedure for reactivation and visualization of enzymic activity. N-Acetyl cysteine is used as the reactivator and 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl-2H-tetrazolium bromide for visualization in a tetrazolium-coupled system. This test, both practical and reliable, is a suitable alter...
متن کاملAnalytical evaluation of methods for serum creatine kinase-MB. Electrophoresis, immunoinhibition and solid phase separation.
The purpose of this study was to evaluate immunoassay methods for the measurement of serum cardiac creatine kinase isoenzyme (CK-MB) with respect to sensitivity and specificity. The CK-MB electrophoretic assay (Helena Laboratories) was used as the reference. Two principles of immunoassay were included in the evaluation,--immunoinhibition and solid phase separation. The direct immunoinhibition t...
متن کاملIn Vitro Inhibition of Human Sperm Creatine Kinase by Nicotine, Cotinine and Cadmium, as a Mechanism in Smoker Men Infertility
Background Nicotine, cotinine and cadmium are harmful components of cigarettes that have an effect on human reproductive function. Although the effects of cigarette smoke on male reproductive function is characterized in several articles its mechanism of action is still unknown. In the present study, we investigate the effect of nicotine, cotinine and cadmium on human sperm creatine kinase acti...
متن کاملAbnormal electrophoretic mobility of a creatine kinase MM isoenzyme.
The routine determination of creatine kinase (CK; EC 2.7.3.2) isoenzymes has recently gained acceptance as a diagnostic tool in laboratory medicine (13). Electrophoreticaily three distinct CK isoenzymes can be separated (4, 5). These dimeric bands have been identified throughout the literature as MM, MB, and BB, and originate mainly from skeletal muscle, heart, and brain tissues, respectively. ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 40 2 شماره
صفحات -
تاریخ انتشار 1994