Reliability of spatiotemporal and kinetic gait parameters determined by a new instrumented treadmill system
نویسندگان
چکیده
BACKGROUND Despite the emerging use of treadmills integrated with pressure platforms as outcome tools in both clinical and research settings, published evidence regarding the measurement properties of these new systems is limited. This study evaluated the within- and between-day repeatability of spatial, temporal and vertical ground reaction force parameters measured by a treadmill system instrumented with a capacitance-based pressure platform. METHODS Thirty three healthy adults (mean age, 21.5 ± 2.8 years; height, 168.4 ± 9.9 cm; and mass, 67.8 ± 18.6 kg), walked barefoot on a treadmill system (FDM-THM-S, Zebris Medical GmbH) on three separate occasions. For each testing session, participants set their preferred pace but were blinded to treadmill speed. Spatial (foot rotation, step width, stride and step length), temporal (stride and step times, duration of stance, swing and single and double support) and peak vertical ground reaction force variables were collected over a 30-second capture period, equating to an average of 52 ± 5 steps of steady-state walking. Testing was repeated one week following the initial trial and again, for a third time, 20 minutes later. Repeated measures ANOVAs within a generalized linear modelling framework were used to assess between-session differences in gait parameters. Agreement between gait parameters measured within the same day (session 2 and 3) and between days (session 1 and 2; 1 and 3) were evaluated using the 95% repeatability coefficient. RESULTS There were statistically significant differences in the majority (14/16) of temporal, spatial and kinetic gait parameters over the three test sessions (P < .01). The minimum change that could be detected with 95% confidence ranged between 3% and 17% for temporal parameters, 14% and 33% for spatial parameters, and 4% and 20% for kinetic parameters between days. Within-day repeatability was similar to that observed between days. Temporal and kinetic gait parameters were typically more consistent than spatial parameters. The 95% repeatability coefficient for vertical force peaks ranged between ± 53 and ± 63 N. CONCLUSIONS The limits of agreement in spatial parameters and ground reaction forces for the treadmill system encompass previously reported changes with neuromuscular pathology and footwear interventions. These findings provide clinicians and researchers with an indication of the repeatability and sensitivity of the Zebris treadmill system to detect changes in common spatiotemporal gait parameters and vertical ground reaction forces.
منابع مشابه
Agreement between the spatio-temporal gait parameters from treadmill-based photoelectric cell and the instrumented treadmill system in healthy young adults and stroke patients
BACKGROUND Treadmill gait analysis was more advantageous than over-ground walking because it allowed continuous measurements of the gait parameters. The purpose of this study was to investigate the concurrent validity and the test-retest reliability of the OPTOGait photoelectric cell system against the treadmill-based gait analysis system by assessing spatio-temporal gait parameters. MATERIAL...
متن کاملQuantifying Gait Impairment Using an Instrumented Treadmill in People with Multiple Sclerosis
Background and Objective. Treadmill gait analysis has been proposed as an attractive alternative for overground walking measuring systems. The purpose of this study was twofold: first to determine spatiotemporal parameters of treadmill gait in patients with multiple sclerosis (MS) and second to examine whether these parameters are associated with specific functional impairments in this cohort. ...
متن کاملInstrumented treadmills: establishing measurement properties is necessary for evaluating clinical interventions
Background Instrumented treadmills that provide basic gait parameters in near real–time are emerging as valuable outcome tools in both clinical and research settings. Significant changes in step length and peak vertical force in the order of 2cm and 20-70N have been reported with footwear interventions and neurological disorders using these systems. However, published data about the systems’ me...
متن کاملValidity and repeatability of inertial measurement units for measuring gait parameters.
Inertial measurement units (IMUs) are small wearable sensors that have tremendous potential to be applied to clinical gait analysis. They allow objective evaluation of gait and movement disorders outside the clinic and research laboratory, and permit evaluation on large numbers of steps. However, repeatability and validity data of these systems are sparse for gait metrics. The purpose of this s...
متن کاملValidation and reliability testing of a new, fully integrated gait analysis insole
BACKGROUND A new tool (OpenGo, Moticon GmbH) was introduced to continuously measure kinetic and temporospatial gait parameters independently through an insole over up to 4 weeks. The goal of this study was to investigate the validity and reliability of this new insole system in a group of healthy individuals. METHODS Gait data were collected from 12 healthy individuals on a treadmill at two d...
متن کامل