The use of computed tomography in pediatrics and the associated radiation exposure and estimated cancer risk.
نویسندگان
چکیده
IMPORTANCE Increased use of computed tomography (CT) in pediatrics raises concerns about cancer risk from exposure to ionizing radiation. OBJECTIVES To quantify trends in the use of CT in pediatrics and the associated radiation exposure and cancer risk. DESIGN Retrospective observational study. SETTING Seven US health care systems. PARTICIPANTS The use of CT was evaluated for children younger than 15 years of age from 1996 to 2010, including 4 857 736 child-years of observation. Radiation doses were calculated for 744 CT scans performed between 2001 and 2011. MAIN OUTCOMES AND MEASURES Rates of CT use, organ and effective doses, and projected lifetime attributable risks of cancer. RESULTS The use of CT doubled for children younger than 5 years of age and tripled for children 5 to 14 years of age between 1996 and 2005, remained stable between 2006 and 2007, and then began to decline. Effective doses varied from 0.03 to 69.2 mSv per scan. An effective dose of 20 mSv or higher was delivered by 14% to 25% of abdomen/pelvis scans, 6% to 14% of spine scans, and 3% to 8% of chest scans. Projected lifetime attributable risks of solid cancer were higher for younger patients and girls than for older patients and boys, and they were also higher for patients who underwent CT scans of the abdomen/pelvis or spine than for patients who underwent other types of CT scans. For girls, a radiation-induced solid cancer is projected to result from every 300 to 390 abdomen/pelvis scans, 330 to 480 chest scans, and 270 to 800 spine scans, depending on age. The risk of leukemia was highest from head scans for children younger than 5 years of age at a rate of 1.9 cases per 10 000 CT scans. Nationally, 4 million pediatric CT scans of the head, abdomen/pelvis, chest, or spine performed each year are projected to cause 4870 future cancers. Reducing the highest 25% of doses to the median might prevent 43% of these cancers. CONCLUSIONS AND RELEVANCE The increased use of CT in pediatrics, combined with the wide variability in radiation doses, has resulted in many children receiving a high-dose examination. Dose-reduction strategies targeted to the highest quartile of doses could dramatically reduce the number of radiation-induced cancers.
منابع مشابه
Assessment of radiation-induced cancer risk to patients undergoing computed tomography angiography scans
Background: Computed tomography angiography (CTA) scan is a suitable imaging technique to evaluate the blood vessels. However, one major disadvantage is the potential risk of cancer related to ionizing radiation exposure during the procedures. The aim of this investigation was to estimate the risk of exposure induced cancer death (REID) values for some common computed tomography angiography (CT...
متن کاملEstimating and comparing the radiation cancer risk from cone-beam computed tomography and panoramic radiography in pediatric and adult patients
Background: This study aimed to estimate and compare the absorbed dose, lifetime cancer risk and mortalities due to cone-beam computed tomography (CBCT) and panoramic examinations on patients. Materials and Methods: The exposure factors were applied to 332 patients in two age groups (6-10, and ˃18-year-old). The dose-area product (DAP) values were measured for CBCT and panoramic radiographies. ...
متن کاملCumulative radiation exposure dose of diagnostic imaging studies in breast cancer patients
Background: Breast cancer is a common disease in radiation oncology. We evaluated the radiation dose received by breast cancer patients, an often-neglected concern. Materials and Methods: The total effective radiation dose in 101 breast cancer patients was calculated by summing the effective doses of individual diagnostic imaging tests from the first hospital visit to the initiation of radiothe...
متن کاملEstimating the Radiation-Induced Cancer Risks in Pediatric Computed Tomography
Introduction One of the central questions in radiological protection is the magnitude of the risks from low doses of radiation, related to the justification and optimization of the diagnostic medical exposures. Therefore, the aim of this study was to estimate the cancer incidence and mortality risks in children of different ages, sizes, and ethnicities undergoing computed tomography examination...
متن کاملPatient-Specific Radiation Dose and Cancer Risk in Computed Tomography Examinations in Ondo, Nigeria
Introduction: The dose in computed tomography (CT) often approach or exceed the optimum levels, thereby increasing the probability of cancer induction. With wide application of this diagnostic test, it is expedient to determine the effective dose (ED) for each patient to estimate their cancer risk. This study was conducted to investigate the patient-specific dose (PSD) and cancer risk in CT exa...
متن کاملLocal Diagnostic Reference Levels for Common Computed Tomography Procedures at a Tertiary Hospital in South Africa
Introduction: An operational computed tomography (CT) scanner is a major source of human exposure to ionizing radiation. Exposure increases the risk of cancer and aplastic anaemia. All radiation exposures should be justified and optimized to meet the clinical objective. In order to avoid the administration of excessive radiation dose to patients, diagnostic reference l...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- JAMA pediatrics
دوره 167 8 شماره
صفحات -
تاریخ انتشار 2013