Comparison of costs and safety of a suture-mediated closure device with conventional manual compression after coronary artery interventions.

نویسندگان

  • Hans Rickli
  • Martin Unterweger
  • Gabor Sütsch
  • Hans Peter Brunner-La Rocca
  • Markus Sagmeister
  • Peter Ammann
  • Franz W Amann
چکیده

The aim of this study was to assess costs and safety of immediate femoral sheath removal and closure with a suture-mediated closure device (Perclose, Menlo Park, CA) in patients undergoing elective (PCI). A total of 193 patients was prospectively randomized to immediate arterial sheath removal and access site closure with a suture-mediated closure device (SMC; n = 96) or sheath removal 4 hr after PCI followed by manual compression (MC; n = 97). In the SMC group, patients were ambulated 4 hr after elective PCI if hemostasis was achieved. In the MC group, patients were ambulated the day after the procedure. In addition to safety, total direct costs including physician and nursing time, infrastructure, and the device were assessed in both groups. Total direct costs were significantly (all P < 0.001) lower in the SMC group. Successful hemostasis without major complication was achieved in all patients. The time to achieve hemostasis was significantly shorter in the SMC group (7.1 +/- 3.4 vs. 22.9 +/- 14.0 min; P < 0.01) and 85% of SMC patients were ambulated on the day of intervention. Suture-mediated closure allows a reduction in hospitalization time, leading to significant cost savings due to decreased personnel and infrastructural demands. In addition, the use of SMC is safe and convenient to the patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Complications of a percutaneous suture-mediated closure device versus manual compression for arteriotomy closure: a case-controlled study.

PURPOSE To evaluate the incidence and types of complications encountered with use of a percutaneous suture-mediated closure device versus manual compression for arteriotomy closure in a retrospective case-controlled study. MATERIALS AND METHODS The authors identified 100 consecutive patients, 15 men and 85 women 21-85 years of age (mean, 50 years), between December 2000 and July 2001 in whom ...

متن کامل

Comparison of vascular closure devices vs manual compression after femoral artery puncture: the ISAR-CLOSURE randomized clinical trial.

IMPORTANCE The role of vascular closure devices (VCD) for the achievement of hemostasis in patients undergoing transfemoral coronary angiography remains controversial. OBJECTIVE To compare outcomes with the use of 2 hemostasis strategies after diagnostic coronary angiography performed via transfemoral access-a VCD-based strategy with 2 types of devices, an intravascular device and an extravas...

متن کامل

Predictors of complications associated with closure devices after transfemoral percutaneous coronary procedures.

To purchase reprints, contact The InnoVision Group, 101 Columbia, Aliso Viejo, CA 92656. Phone, (800) 8092273 or (949) 362-2050 (ext 532); fax, (949) 362-2049; e-mail, [email protected]. devices approved by the Food and Drug Administration have replaced manual compression and are associated with decreased length of stay and increased comfort and satisfaction for patients. These devices include ...

متن کامل

From the Southern Association for Vascular Surgery Can the Perclose suture-mediated closure system be used safely in patients undergoing diagnostic and therapeutic angiography to treat chronic lower extremity ischemia?

Purpose: Mechanical closure devices for arterial hemostasis after angiography, such as the Perclose suture-mediated closure system, are designed to decrease time to ambulation and improve patient comfort. Although these devices are safe and efficacious, to date there has been little reported about use of the Perclose device in a cohort consisting exclusively of patients with lower extremity per...

متن کامل

Suture-mediated closure of the femoral access site after cardiac catheterization: results of the suture to ambulate aNd discharge (STAND I and STAND II) trials.

Despite advances in other aspects of cardiac catheterization, manual or mechanical compression followed by 4 to 8 hours of bed rest remains the mainstay of postprocedural femoral access site management. Suture-mediated closure may prove to be an effective alternative, offering earlier sheath removal and ambulation, and potentially a reduction in hemorrhagic complications. The Suture To Ambulate...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions

دوره 57 3  شماره 

صفحات  -