S,S,S-Tris(2-ethylhexyl) phosphorotrithioate as an effective solvent mediator for a mexiletine-sensitive membrane electrode.
نویسندگان
چکیده
S,S,S-tris(2-ethylhexyl) phosphorotrithioate proved to be an effective solvent mediator for constructing a mexiletine-sensitive membrane electrode in combination with an ion-exchanger, sodium tetrakis[3,5-bis(2-methoxyhexafluoro-2-propyl)phenyl]borate. Among a series of phosphorus compounds containing phosphoryl (P=O) groups, this solvent mediator showed the highest sensitivity to mexiletine in phosphate-buffered physiological saline containing 0.15 mol L-1 NaCl and 0.01 mol L-1 NaH2PO4/Na2HPO4 (pH 7.4), giving a detection limit of 2x10(-6) mol L-1 with a slope of 58.8 mV decade-1. This is the best reported detection limit of any mexiletine-sensitive electrode developed to date. Owing to its high selectivity toward inorganic cations, the electrode was used to determine the level of mexiletine in saliva, the monitoring of which is quite effective for controlling the dose of this drug noninvasively. The mexiletine concentrations determined with the mexiletine-sensitive electrode compared favorably with those determined by high-performance liquid chromatography.
منابع مشابه
New cadmium(II)-selective electrode based on a tetraazacyclohexadeca macrocyclic ionophore.
A poly(vinyl chloride)-based membrane of 3,4:11,12-dibenzo-1,6,9,14-tetraazacyclohexadecane with sodium tetraphenyl borate (NaTPB) as an anion excluder and dibutylphthalate (DBP), dibutyl(butyl)phosphonate (DBBP), tris(2-ethylhexyl)phosphate (TEHP) and tributyl phosphate (TBP) as a plasticizing solvent mediator was prepared and investigated as a Cd2+-selective electrode. The best performance wa...
متن کاملDetermination of Copper Content of Human Blood Plasma by an Ion Selective Electrode based on a New Copper-Selectophore
A new selectophore was introduced for Cu2+ ions. Spectroscopic studies showed a selectivity of a new organic compound (L) toward copper ions and several transitional metal ions. Hence, L was utilized in designing several ion selective electrodes for these cations. In practice, Cu2+ ion selective electrode behaved Nernstian (slope of 27.95±0.3 mV decade-1) over a...
متن کاملHigh-Sensitive and Selective Liquid Membrane Electrode for Direct Determination of Trace Amounts of Chromium
N-(2H-[1,2,4]thiadiazolo[2,3-a]pyridine-2-ylidene)benzamide was used as a selective sensing material in the PVC membrane to construction of a new chromium ion selective electrode. This liquid membrane electrode worked well with a Nernstian response of 19.7 ±0.4 mV decade-1 of Cr(III) in a wide dynamic concentration range of 8.0× 10-6-1.0×10-1 M. The electrode had relatively short response time ...
متن کاملSelective Membrane Electrode for Bromide Ion Based on Aza Pyrilium Ion Derivative as a new Ionophore.
A highly selective electrode for Bromide ion based on aza pyrilium derivative as an excellentionophore is described.The sensor exhibits a good linear response with a slope of ( 60±1 ) mV per decadeover the concentration range of ( 1×10-3 – 9×10-6 M ) , and a detection limit of ( 3×10-6 M ) of Bromideions .The electrode response is independent of pH in the range of(4.0 –9.5).Selectivity coeffici...
متن کاملDetermination of the pH difference across a cell membrane using a methylammonium-selective membrane electrode.
A method was developed for determining pH differences across cell membranes using a methylammonium-selective membrane electrode, based on monitoring of the pH gradient-induced uptake of methylammonium in situ. The methylammonium electrode was constructed using calix[6]arene-hexaacetic acid hexaethyl ester as a neutral carrier and bis(2-ethylhexyl) sebacate as a membrane solvent in a poly(vinyl ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Analytical and bioanalytical chemistry
دوره 387 6 شماره
صفحات -
تاریخ انتشار 2007