Verification of an Automated, Digital Dispensing Platform for At-Will Broth Microdilution-Based Antimicrobial Susceptibility Testing.

نویسندگان

  • Kenneth P Smith
  • James E Kirby
چکیده

With rapid emergence of multidrug-resistant bacteria, there is often a need to perform susceptibility testing for less commonly used or newer antimicrobial agents. Such testing can often be performed only by using labor-intensive, manual dilution methods and lies outside the capacity of most clinical labs, necessitating reference laboratory testing and thereby delaying the availability of susceptibility data. To address the compelling clinical need for microbiology laboratories to perform such testing in-house, we explored a novel, automated, at-will broth microdilution-based susceptibility testing platform. Specifically, we used the modified inkjet printer technology in the HP D300 digital dispensing system to dispense, directly from stock solutions into a 384-well plate, the 2-fold serial dilution series required for broth microdilution testing. This technology was combined with automated absorbance readings and data analysis to determine MICs. Performance was verified by testing members of the Enterobacteriaceae for susceptibility to ampicillin, cefazolin, ciprofloxacin, colistin, gentamicin, meropenem, and tetracycline in comparison to the results obtained with a broth microdilution reference standard. In precision studies, essential and categorical agreement levels were 96.8% and 98.3%, respectively. Furthermore, significantly fewer D300-based measurements were outside ±1 dilution from the modal MIC, suggesting enhanced reproducibility. In accuracy studies performed using a panel of 80 curated clinical isolates, rates of essential and categorical agreement and very major, major, and minor errors were 94%, 96.6%, 0%, 0%, and 3.4%, respectively. Based on these promising initial results, it is anticipated that the D300-based methodology will enable hospital-based clinical microbiology laboratories to perform at-will broth microdilution testing of antimicrobials and to address a critical testing gap.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of broth microdilution, Etest, and agar disk diffusion methods for antimicrobial susceptibility testing of Lactobacillus acidophilus group members.

In recent years, the absence of acquired antimicrobial resistance has become an important criterion to evaluate the biosafety of lactobacilli used as industrial starter or probiotic cultures. At present, however, standards for susceptibility testing of Lactobacillus strains or approved guidelines for interpreting the test results are not available. Hence, this study was carried out to contribut...

متن کامل

Effects of inoculum size and incubation time on broth microdilution susceptibility testing of lactic acid bacteria.

Inoculum size and incubation time were varied during broth microdilution testing of the susceptibilities of 35 strains of lactic acid bacteria to six antibiotics. An increase in either parameter resulted in elevated MICs for all species. An inoculum of 3 x 10(5) CFU/ml is recommended to assess the antibiotic susceptibilities of these bacteria by using broth microdilution.

متن کامل

Investigation of Linezolid Resistance in Staphylococci and Enterococci.

The objective of this study was to investigate an apparent increase in linezolid-nonsusceptible staphylococci and enterococci following a laboratory change in antimicrobial susceptibility testing from disk diffusion to an automated susceptibility testing system. Isolates with nonsusceptible results (n = 27) from Vitek2 were subjected to a battery of confirmatory testing which included disk diff...

متن کامل

Comparative evaluation of the E test, agar dilution, and broth microdilution for testing susceptibilities of Helicobacter pylori strains to 20 antimicrobial agents.

The Epsilometer test (E test; AB Biodisk, Solna, Sweden), a new quantitative technique for the determination of antimicrobial susceptibility, was compared to reference methods (agar dilution and broth microdilution) for the antimicrobial susceptibility testing of Helicobacter pylori. Seventy-one H. pylori strains isolated from patients with duodenal ulcers were tested against 20 antimicrobial a...

متن کامل

High-throughput microarray for antimicrobial susceptibility testing

We describe the development of a novel, high-throughput, nano-scale microarray platform for antimicrobial susceptibility testing (AST). The platform allows to process 480 samples at 50 nL volume on a single chip, analyze by fluorescence read-out with an easy dunk-and-rinse step, and the ability to process multiple samples and chips simultaneously. We demonstrate the applicability of this chip f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 54 9  شماره 

صفحات  -

تاریخ انتشار 2016