Knee arthrodesis in failed total knee arthroplasty with severe osteolysis and ipsilateral long-stem total hip arthroplasty.
نویسندگان
چکیده
We report a case of knee fusion after a failed total knee arthroplasty (TKA) with severe osteolysis including the epicondyle and ipsilateral total hip arthroplasty (THA) with long Wagner revision stem (Sulzer Orthopedics, Baar, Switzerland). The conventional devices for arthrodesis were unavailable in this case because of the long Wagner revision stem and poor bone stock. A connector was made between the long Wagner revision stem and an intramedullary nail (IM nail; Solco, Seoul, Korea). The custom-made connector was coupled with a femoral stem by cylindrical taper fit with additional cement augmentation and an intramedullary nail by screws. Osseous fusion was achieved without pain or instability.
منابع مشابه
Long- Stem Total Knee Arthroplasty for Proximal Tibial Stress Fractures in the Elderly Patients
Background: Presentation of proximal tibia stress fracture is not infrequent among elderly patients due to their poorbone stock. Optimal management of patients with severe gonarthrosis of the knee and concurrent tibial stress fracture isnot known yet. In this study we report the outcome of primary total knee arthroplasty (TKA) using stemmed componentsin elderly patients.Methods: Between 2009 an...
متن کاملTotal Knee Arthroplasty in Patients with Ipsilateral Fused Hip: A Technical Note
We report the surgical technique used to perform posterior-stabilized total knee arthroplasty (TKA) in two patients with a well positioned and functional hip arthrodesis. Intraoperatively, the operating table was placed in an increased Trendelenburg position. Episodically, we flexed the foot of the table by 90° to allow maximal knee flexion to facilitate exposure and bone cuts. We opted to rese...
متن کاملArthrodesis Using Pedicled Fibular Flap After Failed Infected Knee Arthroplasty
OBJECTIVE Severe bone loss associated with failed revision total knee arthroplasty is a challenging scenario. The pedicled fibular flap is a method to obtain vascularized bone for use in knee arthrodesis after failure of a total knee arthroplasty, with substantial loss of bone. METHODS We report 2 successful knee arthrodeses using this method in patients with infected, failed multiply revised...
متن کاملThe Effect of Total Knee Arthroplasty on Hindfoot Alignment in Patients with Severe Genu Varum and Genu Valgum
Background: The maintenance of deformity in the ankle and hindfoot after correction of knee deformity following kneearthroplasty may cause abnormal tension in the knee and patient dissatisfaction. The aim of this study was to determinethe effect of knee arthroplasty on the hindfoot alignment in patients with severe genu varum and valgum.Methods: A total of 84 patients with pri...
متن کاملKnee Fusion or Above-The-Knee Amputation after Failed Two-Stage Reimplantation Total Knee Arthroplasty
Prosthetic joint infection (PJI) is a serious complication of total knee arthroplasty (TKA). Control of infection after a failed two-stage TKA is not always possible, and the resolution of infection may require an above-knee amputation (AKA) or a the-knee (KF). The purpose of this review is to determine which treatment method (AKA or KF) yields better function and ambulatory status for patients...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of arthroplasty
دوره 24 2 شماره
صفحات -
تاریخ انتشار 2009